Independent analysis by NHI Mgmt GroupSource article: Crayonic, “The tube is a computer: why hospital pneumatic tube systems are an identity problem” (November 11, 2026)

TL;DR: Hospital pneumatic tube systems now behave like networked computers with hard-coded credentials, unsigned firmware and vendor maintenance paths that can disrupt care, according to Crayonic. Treating them as building equipment leaves hospitals exposed to identity and lifecycle failures that conventional facility controls do not govern.


At a glance

What this is: NHI Mgmt Group's analysis, drawing on Crayonic's blog post: Hospital pneumatic tube systems blur operational technology and identity governance, and hard-coded credentials, unsigned firmware and vendor access make them a security dependency.

Why it matters: Identity, access and lifecycle controls have to extend to clinical infrastructure because a compromised or unsupported tube system can become a patient-care outage, not just a device issue.


Context

A hospital pneumatic tube system is a networked building service that moves specimens, medications and other clinical material, but it behaves like a computer because it runs software, accepts administrative access and depends on firmware. That makes it an identity and access problem as much as an operational one.

Crayonic's framing matters because the trust boundary is not the carrier in the ceiling tiles but the accounts, update paths and remote support routes behind it. When those controls are weak, hospitals inherit the risk of a managed system they do not fully own.

That starting point is typical for legacy clinical infrastructure: the technology is critical, but the governance model usually lags the operational dependency.


Key questions

Q: How do hospital teams secure pneumatic tube systems as networked assets?

A: Hospital teams should treat pneumatic tube systems like any other managed network asset: identify every station, controller and firmware version, then apply segmentation, named administrative accounts and signed updates. The goal is to make the system observable, revocable and supportable before a failure or compromise forces emergency workarounds.

Q: Why do hard-coded credentials create risk in clinical equipment?

A: Hard-coded credentials create risk because they are embedded in the device or software and cannot be changed easily, so anyone who finds them can reuse the same account or key. In clinical equipment, that can expose service accounts, default passwords, API keys or certificates across many devices, and it blocks normal rotation, revocation and ownership control.

Q: How can unsigned firmware put patient-care systems at risk?

A: Unsigned firmware can let unauthorised code run on patient-care systems because the device cannot verify that an update came from a trusted source. That weakens boot-chain integrity and makes tampering, malware persistence or unsafe function changes harder to detect, especially where firmware controls alarms, dosing, imaging or device communication.

Q: When should vendor maintenance access be reviewed for clinical systems?

A: Vendor maintenance access should be reviewed whenever support relationship changes, account ownership changes, a service contract ends, or remote support paths are modified. That review should confirm named access, least privilege, session logging, MFA, expiry dates and rapid revocation of shared accounts, backdoor credentials or standing remote access.


Technical breakdown

Why hard-coded credentials in tube stations break trust

Hard-coded credentials turn every deployed station into a shared identity surface. Instead of a named technician account with auditability and revocation, the device accepts the same login across installations, which collapses accountability and makes compromise portable. In that model, the credential is not just a secret, it is the access policy. If an attacker learns it, the difference between maintenance access and hostile access disappears. This is why legacy embedded systems become identity problems even when they are described as facility equipment.

Practical implication: Remove shared credentials from clinical devices and require named, revocable administrative identities.

Unsigned firmware creates an unauthenticated control path

Firmware signing is a trust check, not a cosmetic security feature. If a device accepts unsigned or unauthenticated images, it has no way to verify that code came from the expected source or that it was altered in transit. That means the update channel becomes an execution path, not just a maintenance function. In safety-critical environments, the ability to install software is effectively the ability to change how the device behaves. The governance issue is therefore both integrity and provenance.

Practical implication: Block devices that cannot verify signed updates from joining critical clinical networks.

Vendor remote access turns maintenance into an external identity dependency

When a third-party vendor maintains clinical infrastructure, the hospital inherits an extra identity plane: external technicians, remote support paths and scheduled access windows. If that access is not named, time-bounded and logged, the organization cannot distinguish normal maintenance from unnecessary standing access. This is the same governance failure pattern seen in many third-party access cases, only here the target is a patient-care system. The access path matters because the device's availability now depends on someone else's lifecycle discipline.

Practical implication: Treat vendor access as privileged third-party access and review it with the same rigor as internal admin accounts.


Threat narrative

Attacker objective: The attacker aims to gain control over clinical tube infrastructure or force it out of service so hospital operations lose a critical distribution channel.

  1. Entry occurs when a reachable station accepts default or hard-coded credentials over a network service that does not require strong authentication.
  2. Escalation follows when unsigned or weakly validated firmware lets the operator or attacker load code the device cannot authenticate.
  3. Impact appears as loss of trust in the tube system itself, either through remote manipulation or through the outage that follows defensive shutdown and recovery.

Read and download The State of NHI & AI Agent Breach Report 2026, covering 200+ breaches impacting Non-Human Identities including AI Agents.


NHI Mgmt Group analysis

Clinical infrastructure now needs identity governance, not just device management. A pneumatic tube system is operational technology, but its risk profile is governed by accounts, firmware trust and third-party access. When the system can be reached over the network, security teams have to manage who can authenticate, who can update and who can support it. That means the identity model belongs inside the clinical infrastructure programme, not beside it.

Shared credentials are the wrong abstraction for a safety-critical system. The same password across stations turns every device into a clone of every other device, which destroys accountability and makes revocation impossible without a full field reset. In governance terms, the weakness is not merely poor secret hygiene. It is a failure to assign unique administrative identity to a system that now matters to patient care.

Vendor support has become a privileged access problem. Hospitals often think of vendor maintenance as service delivery, but the operational reality is remote administration into a live clinical environment. That access must be governed as if it were privileged third-party identity, because the hospital depends on the vendor's credential discipline as much as on its own. The implication is that support contracts now carry security risk that belongs in access reviews and procurement.

Unsigned firmware is a control failure, not just a vulnerability. The governing assumption is that a device only runs trusted code once it is on the network. That assumption fails when the device accepts any image it is given, because trust is no longer tied to provenance. The implication is that security programmes have to evaluate whether the device can authenticate software at all before they allow it into a clinical segment.

Vendor access without lifecycle offboarding is the named failure mode here. The article shows how a building system can remain exposed because maintenance paths, old stations and unsupported versions outlive the operational relationship that justified them. The control gap is not abstract supply chain risk. It is the inability to retire access when the support model changes, which is exactly how third-party identities turn into long-lived exposure.

From our research library:

What this signals

Vendor access without lifecycle offboarding: Clinical infrastructure fails when maintenance identities outlive the support model that justified them. That is the deeper lesson in hospital tube systems, because an old station or forgotten remote path can remain trusted long after the organization has stopped actively governing it.

Hospitals should expect more safety-critical building systems to look like IT from the identity perspective. Once a device can accept logins, install code and rely on third-party support, the governing question becomes who can act on it, when and under what proof of trust.

Identity reviews for clinical infrastructure need to move from annual paperwork to operational ownership. If a tube system, badge system or similar service depends on a vendor, the access path should be visible in the same programme that governs privileged accounts and third-party offboarding.


For practitioners

  • Inventory tube stations as managed assets Track each station, controller and blower board with firmware version, support status and owner so the system is visible in the asset register.
  • Replace shared admin logins with named accounts Require unique technician identities for local and remote administration, and revoke them when maintenance roles change or end.
  • Verify firmware signing before deployment Refuse unsigned or unauthenticated images and confirm that update paths are cryptographically verified on every device family.
  • Segment the tube network from general hospital traffic Allow only the central controller and approved maintenance endpoints to reach stations, and block cleartext admin services such as Telnet.
  • Schedule vendor access as privileged third-party access Turn remote support on only for approved jobs, log every session and require phishing-resistant MFA for on-site and remote maintenance.

Key takeaways

  • Hospital tube systems now create identity risk because they depend on credentials, firmware trust and vendor access, not because they merely move objects through walls.
  • The strongest evidence in the source is the combination of hard-coded accounts, open remote administration and unsigned firmware paths, which made the system difficult to trust or govern.
  • The practical control response is to inventory these systems, segment them, eliminate shared credentials and manage vendor access as privileged third-party identity.

Related NHI Mgmt Group resources: Identity Convergence Guide · Privacy Notice vs Privacy Policy · Consent Management Guide: Cookies, CMPs and GPC


Standards & Framework Alignment

This section maps relevant standards and security frameworks to the operational risks and controls described in this guidance.

OWASP Non-Human Identity Top 10 and MITRE ATT&CK address the attack and risk surface, while NIST CSF 2.0 sets the governance and control requirements practitioners need to meet.

FrameworkControl / ReferenceRelevance
OWASP Non-Human Identity Top 10NHI-02 — Secret LeakageHard-coded passwords and shared credentials are central to the tube system exposure.
NHI-04 — Insecure AuthenticationOpen Telnet and weak device logins make authentication the failure point in this case.
NHI-03 — Vulnerable Third-Party NHIVendor maintenance access and unsupported stations create third-party identity exposure.
Recommendation — Scan embedded systems for leaked or shared secrets and remove any hard-coded credentials from production use. Require strong device authentication and block legacy cleartext admin protocols on clinical equipment. Review third-party access and offboard vendor identities when support agreements or device ownership change.
NIST CSF 2.0PR.AA-05 — Access Permissions, Entitlements and AuthorizationsThe tube network's administrative access model needs explicit entitlement control.
Recommendation — Define and review which accounts can administer clinical systems and remove unnecessary standing access.
MITRE ATT&CKTA0006; TA0011 — Credential Access; Command and ControlThe article's attack pattern hinges on credential abuse and remote administration.
Recommendation — Map device login exposure to credential access and monitor for cleartext remote administration paths.

Key terms

  • PwnedPiper: PwnedPiper is the name given to the vulnerability set disclosed in Swisslog Healthcare's Translogic pneumatic tube system. It became a reference case for embedded clinical infrastructure because it combined hard-coded credentials, weak remote administration and firmware trust failures in a widely deployed hospital system.
  • Pneumatic Tube System: A pneumatic tube system is a facility transport network that moves small carriers through pressurised tubes between locations. Hospitals use it for specimens, pharmacy items and documents, with stations, valves and a central controller routing carriers; from an IT perspective, its control network and user stations may need segmentation and access control.
  • Clinical Infrastructure: Clinical infrastructure is the collection of hospital technology and physical systems that support patient care, such as medical devices, imaging, laboratory, building controls and the networks that connect them. It includes operational technology, endpoints, servers and integrations that must stay available, monitored and segregated from general business systems.
  • Hard-Coded Credentials: Hard-coded credentials are usernames, passwords, API keys, or tokens embedded directly in source code, scripts, firmware, or configuration files. They create persistent access that is hard to rotate, audit, or revoke, increasing the chance of unauthorized use, secret leakage, and lateral movement across systems and workloads.

Deepen your knowledge

NHI governance, agentic AI identity, and machine identity lifecycle are core topics in our NHI Foundation Level course, the industry's only accredited NHI security programme. If you are building or maturing an IAM programme, it is worth exploring.
NHIMG Editorial Note
Published by the NHIMG editorial team on November 25, 2026.
NHI Mgmt Group, the independent authority on Non-Human Identity, IAM, and Agentic AI security. nhimg.org