Digital forensic work done for the criminal justice system in England and Wales now sits under a statutory Code of Practice, and a provider that cannot show compliance has to say so in its reports. The Forensic Science Regulator Act 2021 gave the Regulator power to publish a Code, investigate and issue compliance notices, and version 2 of the Code came into force on 2 October 2025, replacing version 1, which had applied since 2 October 2023. This guide explains which digital forensic activities the Code covers, how accreditation to ISO/IEC 17025:2017 fits, what a compliance declaration must cover, and what the Code expects for validating digital tools and methods. It is written for UK digital forensic units in police forces and private providers, and for those who commission their work. Status checked against GOV.UK and legislation.gov.uk in November 2026. For forensic method itself, see the Digital Forensics (DFIR) Guide.
Key takeaways
- Version 2 is the Code in force. Published on 5 June 2025, it came into force at 00:01 on 2 October 2025; version 1 is withdrawn.
- Coverage follows the activity, not the job title. Anyone carrying out a listed forensic science activity (FSA) for the criminal justice system in England and Wales is in scope, including police officers and staff.
- Most digital FSAs need ISO/IEC 17025:2017 accreditation. DIG 100 (storage devices), DIG 200 (cell site analysis), DIG 300 and DIG 301 (video) and DIG 400 (audio) are subject to the Code, with framework routes for some video and audio work.
- Every formal report carries a declaration. Section 31.3 sets three forms: full compliance, compliance for new or infrequently used methods with an annex, and non-compliance with an annex on gaps and mitigations.
- Tool changes can break validation. Section 97.4 says any change to hardware, firmware, scripts or operating system may invalidate validation, so every patch needs a risk assessment.
What the FSR Code is
The Code is a statutory Code of Practice for forensic science activities, prepared by the Forensic Science Regulator under section 2 of the Forensic Science Regulator Act 2021. It is a long document (the version 2 PDF runs to 388 pages) organised in parts. The main ones for digital units are:
| Part | What it covers | Why digital units care |
|---|---|---|
| Introduction and Part A | Statutory basis, scope, the Regulator's powers, routes to compliance, investigations and compliance notices | Defines who is a forensic unit and what must be declared |
| Part B | Quality requirements: competence (22), methods and validation (24), data integrity (26), software (28), item handling (29), reporting and declarations (31) | The day-to-day quality system an assessor will test |
| Part D, D1 and D2 | FSA definitions, including DIG 100 to DIG 400 in sections 70 to 74, and DIG 101, DIG 102 and DIG 401 in sections 85 to 87 | Whether your activity is in scope and which route applies |
| Part D3 | Activity-specific requirements, including section 97 Digital forensics and section 98 for video processing and analysis | Digital-specific risk, validation and kiosk rules |
The Regulator may also publish guidance. Section 1.3.4 says departing from guidance is not by itself non-compliance with the Code, but a unit that departs must still show the Code's requirements are met.
Statutory status
- Making the Code: section 3 of the Act requires consultation, approval of a draft by the Secretary of State, laying before Parliament and approval by a resolution of each House before the Regulator publishes the Code or alterations. The Code comes into force on the day it specifies.
- Effect in court: section 4 says a failure to act in accordance with the Code does not of itself make a person liable to civil or criminal proceedings, but the Code is admissible in evidence in criminal and civil proceedings and a court may take into account a failure to follow it.
- Investigation (section 5): the Regulator may investigate where it has reason to believe an FSA is being carried out in a way that creates a substantial risk to an investigation or the course of justice. Code section 7.3.2 says an investigation is not in itself an adverse finding.
- Compliance notices (section 6): the Regulator may issue a compliance notice or seek an injunction. Code section 7.4.3 calls a compliance notice an adverse finding that must be disclosed under the Criminal Procedure and Investigations Act 1996 and the Criminal Practice Directions 2023; section 7.4.2 says compliance action must be declared until a completion certificate is issued under section 7 of the Act.
- Geography: the Code applies to FSAs for criminal justice matters in England and Wales (Code section 1.4.4).
Digital forensic activities in scope
Table 1 in Code section 3.4.1 lists the digital FSAs. The Code applies to five of them now; three are defined but not yet subject to the Code.
| FSA | Name | Code applies | Route to compliance (summary) |
|---|---|---|---|
| DIG 100 | Data capture, processing and analysis from digital storage devices | Yes | Code including section 97, with ISO/IEC 17025:2017 accreditation for sub-activities in 70.3.1 |
| DIG 101 | Analysis of communications network data | No | Not yet required |
| DIG 102 | Digital network capture and analysis | No | Not yet required |
| DIG 200 | Cell site analysis for geolocation | Yes | Code including section 99, with ISO/IEC 17025:2017 accreditation |
| DIG 300 | Recovery and processing of footage from CCTV and video surveillance systems | Yes | Accreditation, or the NPCC Framework for Video Based Evidence for set processing sub-activities, with a limited-scope route where a clip or still is the final output |
| DIG 301 | Specialist video multimedia recovery, processing and analysis | Yes | Code including section 98 where relevant, with ISO/IEC 17025:2017 accreditation |
| DIG 400 | Audio acquisition, conversion and processing | Yes | Accreditation, or the NPCC framework for listed sub-activities |
| DIG 401 | Speech and audio analysis | No | Not yet required |
DIG 100 in detail
- In scope (section 70): screening media for seizure or prioritisation, such as triage software, and capturing, processing, analysing and interpreting data from submitted or seized devices, at scenes, fixed facilities or mobile facilities. Device unlocking and passcode recovery are part of data capture (97.2.3).
- Not requiring accreditation: opinion on the effect of viruses or malware (70.3.2), though the Code still applies.
- Excluded examples: offender-management screening, port screening under Schedule 7 of the Terrorism Act 2000 with an off-the-shelf tool, manual categorisation of indecent images, tachograph analysis, downloads from digital evidence management systems, Overseas Production Orders, OSINT-type data recovery and certain cloud acquisitions. Read the full exclusion list in section 70 before deciding an activity is out of scope.
- Kiosks: sections 97.4.13 to 97.4.15 allow frontline staff to use locked-down, centrally configured off-the-shelf tools beyond the accreditation schedule, if criteria in 97.4.14 a to j are met, including notifying the Regulator, holding accreditation for the method, configuration control, competence, a controlled SOP, awareness of limitations and false negatives, audit and records. These deployments are compliant but not accredited, and reports must say so using the prescribed statement.
Mobile and disk acquisition practice is covered in the Mobile Forensics Guide and the Disk Imaging and Forensic Acquisition Guide.
Accreditation and ISO/IEC 17025
Code section 3.2.5 says that where accreditation is required, the United Kingdom Accreditation Service (UKAS) assesses against ISO/IEC 17025:2017, ISO/IEC 17020:2012 or BS EN ISO 15189:2022. All the digital FSAs above that require accreditation name ISO/IEC 17025:2017. Section 3 sets out the broad routes:
| Route | What it means | Digital examples |
|---|---|---|
| Full Code compliance with accreditation | Code requirements plus accreditation to the specified standard, with the activity on the unit's schedule | DIG 100 laboratory extraction and analysis; DIG 200; DIG 301 |
| Part A plus a specified framework | Compliance with Part A and an approved framework rather than accreditation (section 3.3) | Parts of DIG 300 and DIG 400 under the NPCC Framework for Video Based Evidence |
| Compliant, not accredited, with declaration | Meeting defined criteria and declaring the non-accredited status | DIG 100 kiosks meeting 97.4.14 |
| Not yet required | FSAs defined in Part D2 | DIG 101, DIG 102, DIG 401 |
ISO/IEC 17025 supplies the general laboratory competence framework: impartiality, a management system, method validation, measurement traceability and reporting. The Code adds forensic-specific requirements on top. Accreditation scope matters: an assessor checks that each method and location you use is on your schedule. See the Digital Forensics Tool Certifications Guide for how vendor tool training differs from unit accreditation.
Validation and quality
Validation is where most digital units spend their effort. The general rules are in section 24 and the digital-specific ones in section 97.
Section 24: what a validation must contain
- End-user requirements (24.4): who uses the output, what it must produce, regulatory needs and expected quality, written as testable single statements.
- Specification (24.5): a detailed specification including technical quality standards.
- Risk assessment (24.6): risks to the criminal justice system, including method errors and where specialist skill is needed, under version control.
- Acceptance criteria (24.8): set before experimental work starts. Section 24.3 says failed criteria cannot be corrected mid-validation, and validation must stay separate from development.
- Validation plan (24.9): documented and signed off before testing.
- Independent review and outcomes (24.10, 24.11): the evaluator must be independent of development.
- Report and statement (24.12, 24.13): a validation report and a short statement of validation completion.
- Library and implementation (24.14, 24.15): keep the core documents and plan training, monitoring and post-implementation review.
Vendor or third-party validation data can be used, but section 24.3.2 requires it to be reviewed for adequacy and relevance. Adopted methods still need verification that they work in your hands (24.9.11 onwards, 97.4.7 to 97.4.9).
Section 97: digital-specific requirements
- Methods (97.3): a method is the whole sequence of software, hardware, tools and practitioner actions. Guard against a single technical failure causing irrecoverable data loss, which means backup and redundancy.
- Risk assessment (97.4.1 to 97.4.5): assess risks such as altering data, returning incomplete or inaccurate data and wrongly declaring media unreadable, using a formal method such as failure modes and effects analysis, and cross-reference controls to validation tests.
- Minor changes (97.4.10, 97.4.11): any change to hardware, firmware, scripts or the operating system may invalidate validation, and every proposed change, even a small patch, must be risk assessed.
- Implementation plan (97.4.12): cover configuration management, dependencies, bug handling and patch control.
- Technical records (97.1): record the state, mode and physical condition of seized devices, with labelling and photographs where relevant.
- External services (97.2): couriers, phone repair and unlocking providers are covered, with continuity, Regulator notification and risk assessment requirements.
- Software (28.1) and data integrity (26): software that affects results must be validated or verified under configuration control, and procedures must keep information accurate, authentic and intact, including through migration and compression.
Continuity and exhibit handling are covered in section 29; for practice, see the Evidence Handling and Chain of Custody Guide.
Compliance declarations
Section 3.2.6 requires practitioners to declare compliance in their reports, and section 31 sets the detail. Oral and initial reports such as an MG22A do not need a declaration (31.2.1); streamlined forensic reports, factual reports, expert reports and certificates do, along with a defined quality check (31.2.2).
| Declaration form (31.3.2) | When used | What must accompany it |
|---|---|---|
| Full compliance | The activity was carried out in compliance with the Code | No annex |
| Compliance for infrequently used or new methods | Methods used rarely (no more than once in three months across the unit, per 24.2.8 onwards) or newly introduced | Annex describing the steps taken |
| Non-compliance | The activity did not fully meet the Code | Annex on the gaps and mitigations, covering the topics in 31.3.3 |
| Kiosk statement | DIG 100 deployments under 97.4.14 | Prescribed statement of non-accredited but compliant status (97.4.14 j) |
For SFR1 reports, section 31.3.4 allows an organisational declaration with traceable contact details such as a role title. Use the exact wording the Code prescribes; do not paraphrase it.
Implementing and measuring compliance
- Map activities to FSAs: list every digital task you perform, at every site and in every vehicle, and assign the DIG code and sub-activity, or record why it is excluded with the section reference.
- Gap-assess against version 2: compare procedures against Part A, Part B sections 22 to 31 and section 97, since version 2 replaced version 1 on 2 October 2025.
- Fix the declaration templates: update report templates to the section 31.3 wording, with annex templates for new-method and non-compliance cases.
- Bring validation under change control: link every tool version, firmware and script to a validation or verification record, and route tool updates through the 97.4.10 risk assessment before use in casework.
- Extend the accreditation schedule to cover methods and locations actually in use, including mobile facilities.
- Govern kiosks: notify the Regulator, lock configuration centrally and audit usage against 97.4.14.
Useful measures:
- Percentage of in-scope digital activities on the accreditation schedule or a recognised framework route.
- Number of reports issued with a non-compliance declaration, by FSA, trending down.
- Tool versions in casework with no current validation or verification record (target zero).
- Median days from vendor tool release to completed change risk assessment and verification.
- Kiosk audit findings per quarter and time to close them.
Common failure patterns
- Auto-updating extraction tools: a vendor update is installed and used on casework before the 97.4.10 risk assessment and verification, so the method in use is no longer the validated one.
- Relying on vendor validation alone: the unit cites the vendor's test data without the adequacy and relevance review in 24.3.2 or its own verification.
- Triage treated as out of scope: screening for seizure or prioritisation is part of DIG 100, so scene triage without a compliant route is a gap.
- Generic declarations: a boilerplate compliance line appears on reports where the method was new, rare or not on the schedule, instead of the annexed forms in 31.3.2.
- Unmanaged external unlocking: device unlocking is sent to a third party without the Regulator notification, risk assessment and continuity declaration in 97.2.
- Working from version 1: procedures and templates still reference the withdrawn 2023 Code.
Framework mapping
| Code requirement | NIST CSF 2.0 | NIST SP 800-53 Rev 5 | ISO/IEC 27001:2022 Annex A |
|---|---|---|---|
| Data integrity and continuity (26, 29) | RS.AN-07 | AU-9 | A.5.28 Collection of evidence |
| Records of actions (97.1, 31) | RS.AN-06 | IR-4 | A.5.28 Collection of evidence |
| Tool change control (97.4.10 to 97.4.12) | PR.PS-01 | CM-3 | A.8.32 Change management |
These are security frameworks, not substitutes for the Code: use them to align a unit's information security controls with its forensic quality system.
Practitioner checklist
- Confirm all procedures, templates and training reference Code version 2, in force from 2 October 2025.
- Map every digital task, site and vehicle to a DIG FSA or a documented exclusion.
- Check the accreditation schedule covers every method and location used in casework.
- Use the exact section 31.3 declaration wording, with annexes for new, rare or non-compliant methods.
- Hold a validation or verification record for every tool version, firmware and script in use.
- Risk assess every tool change, including small patches, before casework use.
- Review vendor validation data for adequacy and relevance, then verify in your own hands.
- Meet all 97.4.14 criteria and Regulator notification before deploying kiosks.
- Track and disclose any compliance notice until a completion certificate is issued.
Standards and references
- Forensic Science Regulator: Forensic science activities statutory code of practice, version 2
- Forensic Science Regulator: Code of practice version 2, accessible text
- legislation.gov.uk: Forensic Science Regulator Act 2021, section 2
- legislation.gov.uk: Forensic Science Regulator Act 2021, section 3
- legislation.gov.uk: Forensic Science Regulator Act 2021, section 4
- Forensic Science Regulator: Statutory code of practice, version 1 (withdrawn)
Related NHI Mgmt Group resources: Digital Forensics (DFIR) Guide · Evidence Handling and Chain of Custody Guide · Mobile Forensics Guide · Forensic Readiness Guide. This guide summarises the Forensic Science Regulator's Code of Practice and the Forensic Science Regulator Act 2021 and is not legal advice.