Physical security specifications often quote the wrong standard, or quote the right one without the grade, level or certification route that makes it testable. Intrusion alarms, video surveillance, electronic access control and staff screening each have their own standards from different bodies, with different grading schemes and regional reach, and the UK adds a government authority whose evaluations are not standards at all. This map sets out what each of the main standards covers, who publishes it, where it applies, how its grading works and how conformity is shown, so buyers, assessors and security managers can name the right one in a tender or audit. The standards themselves are paid documents, so this guide summarises scope from the publishers' own pages and does not reproduce their requirements. Standard status was checked on the publishers' pages in November 2026.
Key takeaways
- Match the standard to the system. EN 50131 is for intrusion and hold-up alarms, IEC 62676 (EN 62676 in Europe) for video surveillance, IEC 60839-11 and UL 294 for electronic access control, and BS 7858 for screening the people who work in secure environments.
- A standard without a grade is not a requirement. EN 50131 and IEC 62676 each define four security grades and four environmental classes, and UL 294 defines four performance levels; a specification should state which one applies.
- Region matters. EN standards are adopted across Europe, IEC standards are international, UL 294 is the North American reference for access control units, and BS 7858 and NPSA are UK-specific.
- NPSA evaluates products; it does not publish a public standard. Its Catalogue of Security Equipment lists products that passed NPSA's own evaluations, and the ratings are shared with government and national infrastructure sites rather than published.
- Physical standards do not settle cyber security. Networked alarms, cameras and controllers still need the hardening covered in the system-specific guides linked below.
Standards at a glance
| Standard | Body | Covers | Region | Grading | Current edition (checked November 2026) |
|---|---|---|---|---|---|
| EN 50131 series | CENELEC (BS EN in the UK) | Intrusion and hold-up alarm systems in buildings, wired or wire-free | Europe | Four security grades, four environmental classes | EN 50131-1:2006+A3:2020 (BSI lists it as current, under review); Part 3 revised as EN 50131-3:2026 |
| IEC 62676 series (EN 62676) | IEC; adopted in Europe as EN | Video surveillance systems (formerly called CCTV) for security applications | International and Europe | Four security grades, four environmental classes | IEC 62676-1-1:2013, edition 1.0, stability date 2032 |
| IEC 60839-11 series | IEC Technical Committee 79 | Electronic access control systems and components for physical entry and exit | International and Europe | Defined in the standard text | IEC 60839-11-1:2013, edition 1.0, stability date 2030 |
| UL 294 | UL Standards & Engagement; ANSI approved | Access control system units: construction, performance and operation | North America | Four performance levels, I (lowest) to IV (highest) | Edition 8, ANSI approved 24 May 2023 |
| BS 7858 | BSI | Screening of individuals working in a secure environment (code of practice) | UK | No grades; 5 or 10 year screening periods | BS 7858:2019, listed as current |
| NPSA guidance and evaluation schemes | National Protective Security Authority (part of MI5) | Protective security guidance; evaluation of security products | UK | CLASS ratings for evaluated products, shared with government and national infrastructure | Guidance, not a standard |
How to pick
- Start from the risk assessment: the grade or level should follow from who might attack the site and how capable they are, not from what a supplier offers.
- Name the standard, part, edition and grade: for example, an intrusion system to EN 50131 at a stated grade and environmental class, or access control units listed to UL 294 at a stated performance level.
- Say how conformity is shown: product certification by a test house, installer certification by an inspectorate, or a certificate of compliance at handover.
- Add local requirements: insurer conditions, police response rules and sector regulation can each require more than the base standard.
- Add the cyber layer separately: network, firmware and identity requirements for connected systems.
Intrusion and alarm (EN 50131)
EN 50131 sets requirements for intrusion and hold-up alarm systems (I&HAS) installed in buildings. Part 1 covers system requirements, and further parts cover components such as control and indicating equipment, detectors, warning devices and power supplies. BSI describes BS EN 50131-1:2006+A3:2020 as current and under review; its main change over the 2017 amendment was a new framework for remotely connecting to and controlling alarm systems. Part 3, for control and indicating equipment, was revised as EN 50131-3:2026, replacing the 2009 edition.
- Grades: Part 1 identifies four security grades, which the component parts then use to set performance requirements, and four environmental classes covering indoor and outdoor locations. The grade of every component must be at least the grade of the system. The Intrusion Alarm Systems Security Guide explains what the grades mean for remote access, signalling and cyber controls.
- UK additions: NSI states that newly installed remotely monitored systems in England, Wales and Northern Ireland need to conform to PD 6662:2017 and BS 8243 to get police response, with installers recognised by the police and systems registered under National Police Chiefs' Council policy. Insurers may set the grade.
- Certification: installer approval comes from inspectorates such as NSI, whose Gold level requires an ISO 9001 quality management system.
- Related standard: alarm transmission from the site to an alarm receiving centre is covered by the EN 50136 series.
Video surveillance (EN 62676)
IEC 62676 sets minimum requirements and recommendations for video surveillance systems (VSS) used for security, the term that replaced CCTV. IEC 62676-1-1:2013 covers minimum performance and functional requirements to be agreed between customer, law enforcement where applicable, and supplier. It does not cover design, planning, installation, testing, operation or maintenance, and it excludes remotely monitored detector-activated systems.
| Part | Subject | Use it for |
|---|---|---|
| Part 1-1 | System requirements, general | Setting the security grade, environmental class and functional requirements |
| Part 1-2 | Performance requirements for video transmission | Network transmission performance between cameras, recorders and clients |
| Part 2 | Video transmission protocols | Interoperability between devices from different manufacturers |
| Part 3 | Analogue and digital video interfaces | Interface requirements |
| Part 4 | Application guidelines | Design and operational planning guidance |
Like EN 50131, IEC 62676-1-1 includes four security grades and four environmental classes. In the UK, NSI names BS 8418 as the installation standard for detector-activated remotely monitored video systems. Data protection obligations for camera footage are separate and are covered in the CCTV and Video Surveillance Privacy Guide; network and firmware hardening is in the IP Camera and CCTV Security Guide.
Access control (IEC 60839, UL 294)
The two access control references come from different traditions and are often both cited in global tenders.
| Aspect | IEC 60839-11-1 | UL 294 |
|---|---|---|
| Publisher | IEC Technical Committee 79, Alarm and electronic security systems | UL Standards & Engagement, ANSI approved |
| Scope | Minimum functionality, performance requirements and test methods for electronic access control systems and components used for physical entry and exit | Construction, performance and operation of equipment that regulates entry, exit or access to devices, including related computer equipment needed to grant or deny access |
| Logging | Includes requirements for logging, identification and control of information | Activity reporting may be included, but the accuracy of logged data is not evaluated |
| Grading | Grades defined in the standard text | Four performance levels, I to IV |
| Typical use | European and international specifications | North American product listings |
UL lists remote access requirements, software and firmware upgrades, destructive attack testing and power supply overload and endurance testing among the topics updated in Edition 8. The IEC 60839-11 series has further parts, including the OSDP reader protocol, which the Physical Access Control Systems Security Guide covers with controller hardening and credential choices. For procurement criteria see the Physical Access Control Systems Buyer's Guide.
Screening and vetting (BS 7858)
BS 7858:2019 is a code of practice for screening people who work in a "secure environment", where an insider could steal or compromise data or assets or threaten safety. BSI lists it as current. It applies to all relevant staff, including part-time, temporary and permanent employees, directors, sole traders and partnerships, and is used both by security firms, including those in the SIA Approved Contractor Scheme, and by other sectors such as facilities management, retail and local government.
- Screening period: at least 5 years, or 10 years where a longer period is required, according to NSI's implementation bulletin.
- Conditional employment: work can start after limited screening, with full screening completed within 12 weeks (5-year period) or 16 weeks (10-year period).
- Checks: identity, right to work, employment history, a global watchlist check such as the HM Treasury sanctions list, public record financial checks, and at least one of an SIA licence, an NPCC check or a criminal record disclosure.
- Changes in 2019: wider scope beyond the security sector, more emphasis on risk assessment and top management, character references removed, and social media checks allowed as optional extra information.
- Records: kept for 12 months for unsuccessful candidates and 7 years after employment ends.
Where identity fits: screening is the personnel side of access governance. People cleared under BS 7858 still need joiner, mover and leaver processes that remove badges and system access together. See ISO 27001 Annex A.6 People controls and the Insider Threat Programme Guide.
UK NPSA guidance
The National Protective Security Authority is the UK government's National Technical Authority for physical and personnel protective security and is part of MI5. It absorbed the responsibilities of the Centre for the Protection of National Infrastructure (CPNI) with a broader remit that includes public places, science and technology and academia. It produces guidance and advice, not standards in the formal sense.
- Catalogue of Security Equipment (CSE): lists products that have been tested against NPSA's own security standards and achieved a performance rating. NPSA is not a test house and inclusion is at its discretion. A redesigned product is not covered by the earlier approval.
- Evaluation schemes: for automated access control, NPSA schemes cover the controller and software, tokens, keypads, readers and biometrics. Authorised laboratories test, and a panel of laboratory and NPSA staff decides. Passing products receive a CLASS 1, 2 or 3 rating, which is not publicly advertised but is available to government and national infrastructure sites. An evaluation is valid for two years, with lighter renewals and a full re-evaluation at six years.
- How to use it: government and national infrastructure buyers can specify CSE-listed products at a CLASS level; other organisations can use NPSA's public guidance to shape risk assessments and designs alongside the commercial standards above.
Framework mapping
| Area | NIST SP 800-53 Rev. 5 | NIST CSF 2.0 | ISO/IEC 27001:2022 Annex A (paraphrased) |
|---|---|---|---|
| Access control (IEC 60839, UL 294) | PE-2 Physical Access Authorizations; PE-3 Physical Access Control | PR.AA-06 | A.7.1 security perimeters; A.7.2 physical entry |
| Intrusion and video (EN 50131, EN 62676) | PE-6 Monitoring Physical Access | DE.CM-02 | A.7.4 physical security monitoring |
| Visitors | PE-8 Visitor Access Records | PR.AA-06 | A.7.2 physical entry |
| Screening (BS 7858) | PS-3 Personnel Screening | GV.RR (roles and responsibilities) | A.6.1 screening |
Common failure patterns
- Quoting a standard without a grade or level: suppliers then meet the lowest one.
- Mixing component grades: one lower-grade detector or controller lowers the whole system to that grade.
- Citing an old edition: EN 50131-3 changed in 2026 and UL 294 is on Edition 8; specifications copied from old tenders refer to editions that have been replaced.
- Treating NPSA as a public standard: CLASS ratings are not published, so a supplier claim needs checking through the proper channel.
- Assuming physical certification covers cyber risk: a graded alarm panel or listed controller can still ship with default credentials or old firmware.
- Screening once and never again: BS 7858 screening at hiring does not replace ongoing insider risk controls.
Practitioner checklist
- Record the threat and risk assessment that justifies each grade or level.
- Name the standard, part, edition, grade and environmental class in every specification.
- Require evidence of conformity: product certificates, installer certification and a compliance certificate at handover.
- Check insurer and police response requirements before choosing an alarm grade and signalling route.
- For North American sites, require UL 294 listing with the performance level stated.
- Apply BS 7858 screening to everyone with access to secure areas, including contractors and directors.
- For government or national infrastructure sites, check CSE listings and CLASS levels through NPSA channels.
- Add network, firmware and identity requirements for every connected security system.
- Review the standards list yearly against publishers' catalogues.
Standards and references
- BSI: BS EN 50131-1 Alarm systems, Intrusion and hold-up systems, System requirements
- IEC: IEC 62676-1-1 Video surveillance systems for use in security applications, System requirements, General
- IEC: IEC 60839-11-1 Electronic access control systems, System and components requirements
- UL Standards & Engagement: UL 294 Access Control System Units
- BSI: BS 7858 Screening of individuals working in a secure environment, Code of practice
- NPSA: About NPSA
- NPSA: Automated Access Control Systems (Pedestrian) Evaluation Schemes
- NSI: Technical Bulletin 0049, Implementation of BS 7858:2019
Related NHI Mgmt Group resources: Physical Access Control Systems Security Guide · Intrusion Alarm Systems Security Guide · IP Camera and CCTV Security Guide · ANSI/TIA-942 and EN 50600 Guide