Most attacks on industrial control systems in recent years did not need sophisticated malware: they reached an internet-exposed HMI, typed a default or guessed password and changed setpoints. In May 2025 CISA, the FBI, the EPA and the Department of Energy responded with a short fact sheet, Primary Mitigations to Reduce Cyber Threats to Operational Technology, listing five actions that close those paths. This guide explains each mitigation, what it asks of an asset owner in practice, how to order the work on a real site and how to show it is done. It is written for OT operators, plant and utility engineers, and the security leads who support them. For the wider OT programme (architecture, protocols, standards and monitoring) see the OT Security Guide; this page stays on the five first actions.
Key takeaways
- Five actions, not a framework. Remove OT from the public internet, change default passwords, secure remote access, segment IT from OT, and keep the ability to operate manually.
- The threat is opportunistic and cheap. The agencies describe actors using simple, repeatable tools that anyone with a web browser can use, finding devices through internet scanning search engines and logging in with default or easily guessed passwords.
- Exposure and passwords come first. An exposed HMI with a default password is the single most common pattern; fixing those two together removes most of the opportunistic risk within days.
- Remote access needs a design, not an exception. The fact sheet asks for a private connection or VPN with phishing-resistant MFA, least privilege by asset and role, documented configurations and disabled dormant accounts.
- Manual operation is a security control. If an incident forces you to disconnect, the plant must be able to run, or shut down, safely by hand, and that ability has to be rehearsed.
Background to the guidance
The fact sheet was published on 6 May 2025 by CISA with the FBI, the EPA and the DOE. It states that the agencies were aware of cyber incidents affecting OT and ICS at US critical infrastructure organisations, and that threat actors were deliberately targeting internet-connected OT. It names three weaknesses those actors rely on: OT devices that lack strong authentication and can be found by search engines that scan public IP ranges, default or easily guessed passwords that open-source tools can find, and enterprise networks that more capable actors move through to reach OT.
The guidance was later extended by a joint FBI, CISA and NSA advisory with international partners on pro-Russia hacktivist groups (named in the advisory as CARR, Z-Pentest, NoName057(16) and Sector16). That advisory, published as a supplement to the May 2025 fact sheet, describes scanning for internet-exposed VNC services (typically on TCP port 5900 or nearby ports), password spraying and default or missing passwords on HMIs, then changing setpoints and alarms, defacing screens and in some cases changing credentials to lock operators out, which forced manual operation. Targeted sectors included water and wastewater, food and agriculture, and energy.
| Item | Detail |
|---|---|
| Title | Primary Mitigations to Reduce Cyber Threats to Operational Technology |
| Published | 6 May 2025 (fact sheet, TLP:CLEAR) |
| Authoring agencies | CISA, FBI, EPA, DOE |
| Audience | Owners and operators of OT and ICS in critical infrastructure; useful to any industrial site |
| Alignment | CISA states the mitigations align with the Cross-Sector Cybersecurity Performance Goals (CPGs) |
| Supplementary advisory | FBI, CISA and NSA advisory on pro-Russia hacktivists targeting internet-exposed VNC and HMIs |
The fact sheet is deliberately short. It does not replace ISA/IEC 62443 or NIST SP 800-82, and it should not be read as a complete OT programme. Its value is prioritisation: these are the controls whose absence the agencies kept seeing in real incidents.
The five mitigations
| # | Mitigation (fact sheet wording) | What the agencies ask for | First quick win | Deeper guide |
|---|---|---|---|---|
| 1 | Remove OT connections to the public internet | Identify public-facing assets and remove unintended exposure | Search your own public IP ranges in an internet scanning service and in CISA Cyber Hygiene results; close or broker every OT hit | T0883 Internet Accessible Device |
| 2 | Change default passwords immediately and use strong, unique passwords | Prioritise public-facing devices that can control OT systems or processes | Change HMI, PLC web interface, VNC and router passwords on anything that was exposed, before anything else | Default Credential Breaches Lessons Guide |
| 3 | Secure remote access to OT networks | Re-evaluate remote access risk trade-offs, including contractors'; private IP connection or VPN with a strong password and phishing-resistant MFA; documented configurations; least privilege by asset, role and scope of work; disable dormant accounts | List every remote path (VPN, vendor tools, VNC, cellular modems) and disable accounts with no recent use | OT Remote Access Guide |
| 4 | Segment IT and OT networks | Segment critical systems and use a demilitarised zone (DMZ) to pass control data to enterprise systems | Block direct IT to OT routes at the boundary firewall and move historian and data feeds to a DMZ | OT Network Segmentation, Purdue Model and IEC 62443 Zones and Conduits Guide |
| 5 | Practice and maintain the ability to operate OT systems manually | Routinely test business continuity and disaster recovery plans, fail-safe mechanisms, islanding, software backups and standby systems; confirm manual operation can be done safely | Schedule a tabletop and a supervised manual-operation drill for one critical process | OT Backup, Recovery and Golden Image Guide |
The fact sheet also tells operators to coordinate regularly with managed service providers, system integrators and manufacturers, who can supply system-specific configuration guidance and help prevent misconfigurations. In practice many exposed devices were put online by a third party, so that coordination belongs inside each mitigation, not after them.
1. Remove OT connections to the public internet
- Find exposure from the outside: CISA's Stuff Off Search guidance recommends assessing which assets are reachable from the internet, using scanning services and CISA's free vulnerability scanning (Cyber Hygiene Services), then removing access that operations do not require. Search by your organisation's IP ranges and by the ports your OT uses, such as Modbus TCP 502, EtherNet/IP 44818, S7 102, DNP3 20000 and VNC 5900.
- Look for unmanaged paths: cellular routers at remote pump stations and substations, integrator-installed port forwards and cloud-connected HMIs are the usual sources, and they rarely appear in the IT firewall rulebase.
- Decide per asset: Stuff Off Search asks whether the service is essential, what business need justifies it, whether it can sit behind a VPN with MFA and whether it is patched. For OT the default answer is no direct exposure.
- Keep checking: exposure comes back after maintenance visits. Repeat the external scan monthly and after every contractor change.
2. Change default passwords and use strong, unique passwords
- Order: the fact sheet prioritises public-facing devices that can control OT systems or processes. Then do engineering workstations, HMIs, PLC and drive web servers, managed switches, serial gateways and remote access appliances.
- Unique per device: one shared site password recreates the default problem. Store OT device credentials in a vault or an offline sealed register that operations can reach when the network is down.
- Limit what the account can do: the hacktivist advisory recommends limiting remote or default accounts to view-only where the control system allows it. Where a device has no user model, compensate at the network layer.
- Plan for lock-out: actors in the advisory changed credentials to lock operators out. Keep a tested recovery procedure for HMI and controller passwords, agreed with the vendor.
3. Secure remote access to OT networks
- Re-evaluate the trade-off: the fact sheet asks operators to revisit the risk decisions made when remote access was enabled, including decisions made by contractors. Some paths can simply be removed.
- Connection type: where remote access is essential, move OT assets to a private IP network connection and use a VPN with a strong password and phishing-resistant MFA. CISA's phishing-resistant MFA guidance points to FIDO2/WebAuthn and PKI-based authenticators.
- Least privilege: document each remote access configuration and scope access by asset, user role and scope of work. A vendor who maintains one compressor package needs a session to that package, not the OT network.
- Dormant accounts: disable them. The Colonial Pipeline ransomware attack began with a VPN profile that was no longer used, had never been disabled and had no MFA; the pipeline shutdown that followed was a containment decision.
4. Segment IT and OT networks
- DMZ for data flows: the fact sheet asks for segmentation of critical systems and a DMZ to pass control data to enterprise systems. Historian replicas, patch staging and remote access brokers sit there, and no session crosses from IT to OT in one hop.
- Default deny: the hacktivist advisory adds default-deny firewall policies, restricted inbound and outbound traffic, IP and MAC allowlisting and alerts on unauthorised access attempts.
- Map flows first: keep an accurate asset inventory and data-flow map before tightening rules, or the first blocked flow will be a production outage. See the OT Asset Visibility Guide.
5. Practise and maintain manual operation
- What to test: the fact sheet lists business continuity and disaster recovery plans, fail-safe mechanisms, islanding capabilities, software backups and standby systems.
- Safety first: confirm manual operation can be performed safely. That means trained operators, local controls that work without the HMI, staffing for a sustained period and a clear decision on when to shut down instead.
- Backups that restore: the advisory recommends backing up HMI engineering logic, configurations and firmware and testing recovery. A backup that has never been restored to spare hardware is an assumption, not a control.
Prioritising for your site
The five mitigations are not equal in effort. Exposure and passwords can be fixed in days; segmentation and manual-operation readiness take months and need outages. A practical order:
- Week 1, exposure sweep: run an external search of your public IP ranges and known remote sites, request CISA Cyber Hygiene scanning if you are eligible, and list every OT service found. Disconnect or put behind a VPN anything with no documented business need, after operations confirm no process depends on it.
- Week 1 to 2, passwords: change default and shared passwords on every exposed device first, then on all HMIs, engineering workstations and remote access appliances. Record new credentials in a vault and in a sealed offline copy.
- Weeks 2 to 6, remote access inventory: list every path (corporate VPN, vendor tools, VNC, remote desktop, cellular modems, cloud portals), its owner and its users. Disable dormant accounts, require phishing-resistant MFA at the VPN or broker, and move vendors to session-based, time-bound access. See the OT Third-Party and Integrator Access Guide.
- Months 2 to 6, segmentation: build or confirm the DMZ, block direct IT to OT routes, apply default deny with logging first, then enforce during a planned window. Keep the previous rulebase ready to restore as the rollback.
- Quarterly, manual operation drills: run a tabletop, then a supervised drill on one process at a time. Restore one controller and one HMI from backup to spare hardware each year.
- Ongoing, verify: repeat the external scan monthly and after site work, and review remote accounts quarterly with their owners.
Small sites versus large estates
| Situation | Smaller utility or single plant | Large multi-site operator |
|---|---|---|
| Finding exposure | Free external scanning (CISA Cyber Hygiene for eligible organisations) and a manual review of routers and modems | Attack surface management tooling across all IP ranges and cellular contracts |
| Remote access | One brokered path with MFA; remove ad hoc VNC and remote desktop tools | Central secure remote access platform with per-asset policies, approvals and session recording |
| Segmentation | A firewall between office and control networks with a small DMZ | Zones and conduits per IEC 62443-3-2, site DMZs and central rule governance |
| Manual operation | Written manual procedures and an annual drill with the integrator | Site-specific playbooks, islanding tests and drills linked to the OT incident response plan |
| Help to ask for | Integrator or manufacturer hardening guidance, CISA regional advisors, sector ISAC | Same, plus internal OT security engineering |
Where identity fits
Three of the five mitigations are identity controls: default passwords, remote access authentication and dormant accounts. OT accounts include shared operator logins, vendor accounts and the machine credentials that historians, OPC servers and data diodes use to talk across the DMZ. Give each an owner, store its secret, and review it on a schedule. See the OT and ICS Identity and Access Guide.
Measuring progress
- Internet-exposed OT services: count from monthly external scans; the target is zero.
- Devices on default or shared credentials: percentage of inventoried OT devices, tracked down to zero for anything that can change the process.
- Remote access accounts with phishing-resistant MFA: percentage of active accounts, and number of accounts unused for 90 days still enabled.
- Direct IT to OT flows: number of firewall rules or observed sessions that bypass the DMZ.
- Manual operation readiness: drills completed per critical process per year, and successful restores from backup.
Log and alert on remote logins outside approved windows, new external connections to OT addresses, failed logins on HMIs and VNC, and setpoint or alarm changes, as the advisory recommends. See the OT Network Security Monitoring Guide.
Framework mapping
| Mitigation | CISA CPG | NIST CSF 2.0 | NIST SP 800-53 Rev. 5 | ATT&CK for ICS |
|---|---|---|---|---|
| Remove internet connections | 2.X Limit OT Connections to Public Internet; 2.W No Exploitable Services on the Internet | PR.IR-01, ID.AM-01 | SC-7 | T0883 Internet Accessible Device |
| Change default passwords | 2.A Changing Default Passwords | PR.AA-01 | IA-5 | T1694.001 Default Credentials |
| Secure remote access | 2.H Phishing-Resistant MFA; 2.D Revoking Credentials for Departing Employees | PR.AA-03, PR.AA-05 | AC-17, IA-2, AC-2(3) | T0822 External Remote Services, T0859 Valid Accounts |
| Segment IT and OT | 2.F Network Segmentation | PR.IR-01 | SC-7, SC-7(5) | T0886 Remote Services |
| Manual operation | 2.R System Backups; 2.S Incident Response (IR) Plans | PR.IR-03, ID.IM-04, RC.RP-01 | CP-2, CP-10 | Limits impact rather than a single technique |
CISA states it is updating the CPGs to align with NIST CSF 2.0, so check goal numbering on the CPG page before citing it in an audit.
Common failure patterns
- Checking only the IT perimeter: the exposed HMI sits behind a cellular modem or an integrator's port forward that the corporate firewall team has never seen.
- Changing one password per site: a shared "new" password on every HMI is quickly reused and leaked, and it gives a single login to the whole site.
- VPN without MFA or with stale accounts: a legacy profile left active, as in the Colonial Pipeline case, turns a leaked password into network access.
- A DMZ that is bypassed: dual-homed engineering laptops, a "temporary" any-any rule or a vendor tunnel straight to a PLC undo the segmentation on paper.
- Manual operation that exists only in a binder: procedures written years ago, staff who have never run the process by hand and backups never restored to hardware.
- Treating the five as the whole programme: they are a floor. Monitoring, patching and supplier security still need the wider work in the OT Security Guide.
Practitioner checklist
- Run an external search of every public IP range and remote site for OT services, and repeat it monthly.
- Remove or broker every internet-exposed OT service, after operations confirm process dependencies.
- Change default and shared passwords, exposed devices first, and store unique credentials in a vault with an offline copy.
- Inventory every remote access path, disable dormant accounts and require phishing-resistant MFA.
- Scope vendor access by asset, role and scope of work, and document each configuration.
- Block direct IT to OT routes and move historian and data feeds into a DMZ with default deny.
- Back up HMI logic, controller configurations and firmware, and restore one to spare hardware each year.
- Drill manual operation for each critical process and confirm it can be done safely.
- Agree hardening guidance and remote access rules with integrators and manufacturers.
Standards and references
- CISA: Primary Mitigations to Reduce Cyber Threats to Operational Technology
- CISA, FBI, EPA and DOE: Fact Sheet, Primary Mitigations to Reduce Cyber Threats to Operational Technology (PDF)
- FBI, CISA, NSA and partners: Pro-Russia Hacktivists Conduct Opportunistic Attacks Against US and Global Critical Infrastructure
- CISA: Stuff Off Search
- CISA: Cross-Sector Cybersecurity Performance Goals
- CISA: Layering Network Security Through Segmentation
Related NHI Mgmt Group resources: OT Security Guide · OT Remote Access Guide · OT and ICS Identity and Access Guide · OT Incident Response Guide · Water and Wastewater Cybersecurity Guide