What is a practical example of a Manufacturer Disclosure Statement for Medical Device Security (MDS2)?

← Back to all FAQ
By NHI Mgmt Group Editorial Team Updated October 18, 2026 Domain: Governance, Ownership & Risk

A practical MDS2 example is a hospital using the manufacturer’s disclosure to check whether a connected device supports authentication, logging, patching, encryption, and remote access controls before procurement. Security teams use it to compare devices, identify compensating controls, and document residual risk where a device cannot meet internal requirements.

What an MDS2 Example Looks Like in Practice

A practical MDS2 example starts with procurement, not incident response. The hospital uses the manufacturer’s disclosure to see whether the device supports the security capabilities it expects before it is connected to clinical networks. The value is comparative: it helps buyers ask consistent questions across vendors and spot where a device will need compensating controls.

That review usually focuses on whether the device supports authentication, logging, patching, encryption, and remote access restrictions. Those answers are not just feature checkboxes. They indicate whether the device can fit the hospital’s baseline architecture, or whether the hospital will need to isolate it, restrict connectivity, or accept a documented exception.

For a connected infusion pump, imaging system, monitor, or similar device, the MDS2 often becomes the bridge between vendor claims and security engineering. A product may be clinically suitable but still require extra network segmentation, stricter admin controls, or compensating monitoring if it lacks strong built-in protections. The disclosure gives the security team a common reference point for that decision.

How Teams Use the Disclosure to Make a Buying Decision

An MDS2 is most useful when it is read alongside the hospital’s own technical requirements, not as a standalone guarantee. Security, biomed, clinical engineering, and procurement teams can use it to compare devices on the same criteria, then determine whether the device meets policy or only partially meets it. That makes the document a practical input to procurement, risk acceptance, and deployment planning.

In practice, the team looks for gaps that affect deployment design. If the device cannot encrypt data in transit, for example, the hospital may compensate with network controls. If it cannot support modern authentication, the team may restrict administrative access or place it behind controlled management channels. If logging is limited, the hospital may require additional network telemetry or stronger compensating oversight.

That is why the disclosure matters before purchase. It can prevent a clinical device from becoming a hidden exception after installation. It also gives the organisation an auditable way to explain why a device was accepted despite weaknesses, which is useful when the product is clinically necessary but not fully aligned to internal security standards.

What Makes a Good MDS2 Review

A good review does not stop at whether the form is completed. Teams should check whether the answers are specific enough to support a real deployment decision, then compare them against the intended use case. If the disclosure is vague, outdated, or silent on important controls, the buyer should treat that as a risk signal rather than assuming the device is secure by default.

This is also where compensating controls become important. A device may be acceptable only if the hospital can enforce segmentation, tightly control remote access, restrict who can administer it, or monitor it more closely than other endpoints. The disclosure helps identify those conditions early, before the device is allowed onto a production network.

In that sense, the MDS2 is a decision aid for residual risk. It does not remove the need for local assessment, but it gives the organisation the facts needed to decide whether the device is secure enough for its environment, what must be added around it, and what should be documented for governance and lifecycle review.

Risk and Threat Considerations

Medical devices often have long lifecycles, limited patch flexibility, and operational constraints that make weak security disclosures material rather than theoretical. If the MDS2 understates those limits, the organisation may connect a device to a production network without realising that its authentication, update, or logging model is too weak for the environment.

Failure mechanism: A gap between the manufacturer’s disclosure and the device’s actual controls can lead to over-trust, weak segmentation decisions, and delayed remediation when the device is deployed.

Impact: The result can be harder detection, greater lateral movement opportunity, and a larger blast radius if the device is abused or compromised.

Standards & Framework Alignment

This section maps relevant standards and security frameworks to the operational risks and controls described in this guidance.

NIST SP 800-53 Rev 5 sets the technical controls, while ISO/IEC 27001:2022 defines the regulatory obligations.

FrameworkControl / ReferenceRelevance
NIST SP 800-53 Rev 5IA-9 — Identification and Authentication (Service and Device)MDS2 compares device auth capabilities and access controls.
AU-2 — Event LoggingMDS2 commonly reveals whether a device supports logging and audit visibility.
CM-8 — System Component InventoryProcurement and disclosure review depend on knowing which devices are in scope.
Recommendation — Validate device authentication requirements before approving clinical network access. Require auditable logging for medical devices before production deployment. Inventory connected devices and tie each one to a reviewed disclosure record.
ISO/IEC 27001:2022A.5.9 — Inventory of information and other associated assetsMDS2 supports asset-level review of medical devices before connection.
A.8.9 — Configuration managementMDS2 helps determine whether device security settings and compensating controls are needed.
Recommendation — Maintain an up-to-date inventory of connected medical devices and their security status. Standardise secure configurations and compensating controls for deployed devices.

Practitioner Guidance

What to verify: Treat the MDS2 as evidence to validate, not as proof of safety. Confirm that the disclosed capabilities match the hospital’s required controls for the specific deployment, including administration model, update path, logging visibility, and remote access conditions.

Decision rule: If the device cannot meet a required control directly, decide early whether a compensating control is realistic and enforceable. If not, document the residual risk before purchase rather than discovering the gap after installation.

Practitioner takeaway: The practical value of an MDS2 is not that it says a device is secure, but that it exposes where the hospital must add controls, tighten access, or formally accept residual risk before the device goes live.

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

NHIMG Editorial Note
Reviewed and updated by the NHIMG editorial team on October 18, 2026.
NHI Mgmt Group — the #1 independent authority on Non-Human Identity, IAM, and Agentic AI security. nhimg.org