CVE-2024-23113 is a format string vulnerability in Fortinet Multiple Products. CISA added it to the Known Exploited Vulnerabilities catalogue on 9 October 2024, which means attackers have used it in real attacks. Fortinet FortiOS, FortiPAM, FortiProxy, and FortiWeb contain a format string vulnerability that allows a remote, unauthenticated attacker to execute arbitrary code or commands via specially crafted requests.
What this vulnerability means in practice
CVE-2024-23113 is dangerous because a remote, unauthenticated request can trigger code or command execution in exposed Fortinet management or security appliances. In products that sit on the network edge, that can turn a single parsing flaw into full device compromise.
Format string flaws are especially serious when they occur in internet-facing infrastructure because the vulnerable input is processed before normal authentication or authorization checks can help. For a practitioner, the key question is not only whether the product is present, but whether it is reachable from untrusted networks or exposed through a partner path.
Why format string bugs are so high impact
A format string vulnerability lets attacker-controlled data be interpreted as formatting instructions instead of plain text. That can corrupt memory, leak process state, or steer execution, which is why these bugs are often associated with arbitrary code execution rather than a simple crash.
In appliances, the business impact is amplified by the role of the affected system. If the device mediates remote access, web traffic, administration, or security enforcement, compromise can affect every session or workload that depends on it. The same defect can therefore become both an initial access path and a staging point for broader intrusion.
How organisations should assess exposure and reduce immediate risk
Exposure review starts with an accurate asset inventory, then narrows to which Fortinet products are deployed, which interfaces are enabled, and whether management or user-facing services are reachable from the internet. Vendor advisories and the NIST National Vulnerability Database should be checked alongside the CVE Program record for authoritative identifiers and remediation references.
When patching cannot happen immediately, reduce the attack surface by restricting exposure, limiting administrative paths, tightening allowlists, and placing compensating controls around any externally reachable instance. If the appliance is essential, treat it as a high-priority asset and verify whether traffic filtering or segmentation can remove the vulnerable entry point until remediation is complete.
Detection, remediation, and post-exploitation review
Because the flaw was added to CISA’s Known Exploited Vulnerabilities catalogue, organisations should assume there is real-world exploitation pressure and verify whether the product was contacted by suspicious requests before or after patching. Review logs for unusual request patterns, unexpected command execution indicators, configuration changes, new accounts, altered credentials, or persistence on the device.
Post-patch review matters because fixing the software does not prove the appliance was not already abused. Where compromise is plausible, investigate for follow-on actions such as stolen credentials, modified trust material, or outbound connections that suggest the device was used as a foothold. If the appliance mediated authentication or admin access, rotate any credentials, tokens, or keys that may have been exposed during the incident.
Risk and Threat Considerations
Exploited format string flaws on edge appliances are attractive because they can bypass normal user authentication, deliver high privileges, and often sit in front of sensitive services. That makes the risk more than a single vulnerable host, it can become a gateway to broader network compromise, credential theft, and operational disruption.
Failure mechanism: An attacker sends a crafted request that reaches vulnerable parsing code, causes memory corruption or unsafe execution, and then uses the resulting control to run commands or implant persistence.
Impact: The appliance may be used to intercept traffic, steal secrets, tamper with access controls, pivot deeper into the environment, or disrupt security and remote-access services.
Standards & Framework Alignment
This section maps relevant standards and security frameworks to the operational risks and controls described in this guidance.
NIST SP 800-53 Rev 5 and CIS Controls v8 set the governance and control requirements practitioners need to meet.
| Framework | Control / Reference | Relevance |
|---|---|---|
| NIST SP 800-53 Rev 5 | SI-10 — Information Input Validation | Format string exploitation is prevented by strict input handling before parsing. |
| RA-5 — Vulnerability Monitoring and Scanning | The term is a known exploited CVE, so exposure tracking and scanning are central. | |
| SC-7 — Boundary Protection | The vulnerable products are edge-facing appliances where exposure control materially reduces risk. | |
| Recommendation — Validate externally supplied request data before it reaches formatting or command-handling code. Track vulnerable assets continuously and prioritize remediation for KEV-listed findings. Restrict network reachability to management and service interfaces through boundary controls. | ||
| CIS Controls v8 | CIS-7 — Continuous Vulnerability Management | This CVE requires prioritised identification, validation and remediation of exposed assets. |
| CIS-12 — Network Infrastructure Management | Network-device exposure and segmentation are key to limiting appliance attack surface. | |
| Recommendation — Prioritize and remediate exploited vulnerabilities on externally reachable systems first. Segment and restrict appliance interfaces to reduce exploitable exposure. | ||
Practitioner Guidance
What to watch for: Treat any CVE with KEV status as an exposure-management priority, not a routine backlog item. For internet-facing Fortinet devices, confirm ownership, verify reachability, and establish who can approve emergency containment when patching is delayed.
Practitioner takeaway: If the device is exposed, assumed-safe until proven otherwise is the wrong default, because actively exploited appliance flaws often change from vulnerability management problems into incident-response problems very quickly.
Related resources from NHI Mgmt Group
- CVE-2025-59718 (Fortinet Multiple Products Improper Verification of Cryptographic Signature)
- CVE-2025-25249 (Fortinet Multiple Products Heap-based Buffer Overflow)
- CVE-2025-32756 (Fortinet Multiple Products Stack-Based Buffer Overflow)
- CVE-2024-55956 (Cleo Multiple Products Unauthenticated File Upload)
Deepen Your Knowledge
Free weekly newsletter
Subscribe to the NHI & AI Identity Journal
The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.
Bonus 33% off our NHI Course when you subscribe.
Reviewed and updated by the NHIMG editorial team on October 17, 2026.
NHI Mgmt Group — the #1 independent authority on Non-Human Identity, IAM, and Agentic AI security. nhimg.org