A protection relay is a device in an electrical power system that monitors current, voltage and measurements and trips circuit breakers when it detects a fault or abnormal condition. If an attacker alters its settings or firmware, it can trip needlessly or fail to trip. Defenders restrict engineering access, control setting changes and compare configuration with a baseline.

How protection relays work

Protection relays continuously watch electrical measurements such as current and voltage, then issue a trip signal when a fault or abnormal condition crosses a configured threshold. In a power network, that function is both protective and disruptive: it is meant to isolate dangerous conditions fast enough to protect equipment, but it can also remove a feeder, transformer or substation element from service if it is mis-set or manipulated.

The relay is usually part of a wider protection scheme, so its behaviour depends on coordination with circuit breakers, instrument transformers, communications links and engineering workstations. A correct relay setting is therefore not just a device parameter, but a safety and availability decision for the whole electrical system.

Why relay settings and firmware matter

Protection relays are valuable targets because small changes can have outsized operational effects. If settings are altered, the relay may trip too early, fail to trip during a fault, or respond to conditions outside its intended protection zone. If firmware is modified, an attacker may be able to suppress protection logic, degrade measurement accuracy or disrupt the device’s trusted behaviour.

Those failures matter because relays sit at the boundary between normal operation and equipment damage. A bad configuration can create nuisance outages, while a missed trip can allow faults to persist long enough to damage assets, trigger cascading issues or create unsafe conditions for maintenance crews.

How organisations check exposure and protect the configuration

Exposure assessment starts with knowing which relays exist, where they are deployed, and which engineering paths can reach them. That means maintaining an accurate asset inventory, identifying any remote management interfaces, and verifying whether the device is reachable from corporate networks, vendor support channels or other non-OT paths.

Protective controls should focus on restricting engineering access, separating protection engineering from general administrative access, and treating setting changes as controlled operations with review and approval. Baseline comparison is especially important for relays because the difference between a safe setting file and a dangerous one may be a single threshold, timer or logic flag.

For broader OT hardening, MITRE ATT&CK for ICS T0800 Activate Firmware Update Mode is useful when firmware or maintenance modes are part of the attack path, and MITRE ATT&CK for ICS T0814 Denial of Service helps explain how relay availability can be degraded by overload or disruption. Where operators need to understand silencing or masking behaviour around protection logic, MITRE ATT&CK for ICS T0878 Alarm Suppression provides a useful adjacent control lens.

Detection, recovery and post-change review

Monitoring should look for unexpected setting changes, firmware drift, unusual maintenance access, and breaker operations that do not match the expected fault profile. Because a relay can be altered without immediate symptoms, post-change validation is as important as live monitoring, especially after vendor work, emergency engineering access or incident response activity.

Recovery should include comparing the live configuration against a known-good baseline, checking whether any protection logic was disabled or widened, and confirming that breaker coordination still matches the design intent. If exploitation is suspected, the review must extend beyond the device itself to the accounts, laptops, jump hosts and removable media used to administer it.

Operational consequences for power-system reliability

When relay integrity is lost, the result is rarely confined to one device. A relay that trips incorrectly can remove healthy equipment from service, while a relay that fails to trip can let a local fault spread into a wider outage. In both cases, the business impact is amplified by the relay’s role in fault isolation and selective shutdown.

That is why protection relays are often managed as high-trust OT assets. Their configuration, firmware state and administrative access are part of the resilience posture of the whole power system, not just a maintenance detail.

Standards & Framework Alignment

This section maps relevant standards and security frameworks to the operational risks and controls described in this guidance.

MITRE ATT&CK addresses the attack and risk surface, while NIST SP 800-53 Rev 5 sets the governance and control requirements practitioners need to meet.

FrameworkControl / ReferenceRelevance
MITRE ATT&CKT0800 — Activate Firmware Update ModeProtection relay firmware abuse can involve maintenance mode activation.
T0814 — Denial of ServiceRelay disruption can prevent protection actions or force nuisance trips.
T0878 — Alarm SuppressionRelay tampering can hide abnormal conditions and delay operator response.
Recommendation — Monitor for unauthorized firmware-mode changes and investigate relay maintenance-state transitions. Hunt for relay saturation, comms disruption and fault-response degradation as DoS indicators. Correlate protection events with independent alarms to detect suppressed or masked warnings.
NIST SP 800-53 Rev 5CM-6 — Configuration SettingsRelay settings are security-relevant configuration values that require control and review.
AC-6 — Least PrivilegeEngineering access to relays should be limited to authorized personnel and tasks.
SI-7 — Software, Firmware, and Information IntegrityRelay firmware integrity directly affects protection behaviour and safe tripping.
Recommendation — Establish approved relay baselines and review deviations before returning devices to service. Restrict relay administration to the minimum roles needed for protection engineering. Verify relay firmware integrity and investigate unexpected code or image changes promptly.

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

NHIMG Editorial Note
Reviewed and updated by the NHIMG editorial team on November 26, 2026.
NHI Mgmt Group — the #1 independent authority on Non-Human Identity, IAM, and Agentic AI security. nhimg.org