In IEC 62443-3-2, the system under consideration is the defined set of industrial control system assets that the asset owner scopes for a cyber security risk assessment. It is then divided into zones and conduits, and target security levels are set for each.
What the system under consideration means in IEC 62443-3-2
The system under consideration, or SuC, is the scoping boundary for an industrial control system security assessment. It defines which assets are included, which assets are out of scope, and where the risk assessment begins and ends. That boundary is the foundation for everything that follows in IEC 62443-3-2, because the rest of the method only works once the system has been clearly bounded.
For practitioners, SuC is not just a label for “the system”. It is the agreed assessment object that the asset owner uses to frame cyber security work, define assumptions, and avoid ambiguous scope creep. When the boundary is unclear, the assessment can drift into partial coverage, duplicated effort, or a false sense of completeness.
How SuC relates to zones, conduits, and target security levels
Once the SuC is defined, IEC 62443-3-2 breaks it into zones and conduits. Zones group assets with similar security requirements, while conduits describe the communication paths between those zones. This structure makes the assessment more practical, because security requirements can be applied to groups of assets and to the traffic between them rather than to each device in isolation.
The SuC therefore acts as the parent scope for zone and conduit modelling. If a communication path or asset is left outside the boundary, it may never be evaluated for its effect on segmentation, trust boundaries, or inter-zone access. That is why the SuC definition has to be explicit before security levels are assigned.
The same boundary also supports target security level setting. For each zone, the assessor can decide the level of protection needed for the intended operating context and the consequences of compromise. In practice, that means the SuC is the place where scope turns into an actionable security model.
Why the scoping boundary matters in an OT risk assessment
SuC is especially important in industrial environments because control systems often contain mixed generations of equipment, safety functions, vendor-managed components, and legacy communications. A poorly defined boundary can hide important dependencies, especially where one asset’s compromise can affect another asset’s availability, integrity, or safety behaviour.
It also matters because OT assessments are usually asset-owner led and consequence driven. The SuC sets the practical perimeter for evidence collection, interviews, inventory validation, and the identification of critical flows. Without a defensible boundary, the assessment can miss consequential interfaces or overstate control coverage.
The page for the IEC 62443-3-2 OT Risk Assessment Guide expands this method from definition to workflow, including zone and conduit partitioning, target security levels, and the cybersecurity requirements specification.
The accompanying OT Zones and Conduits Worksheet Template is useful when the SuC needs to be translated into a working inventory of zones, conduits, and exceptions.
How to use SuC correctly in assessment practice
SuC should be treated as a controlled scope decision, not as an informal diagram label. Good practice is to align the defined boundary with the asset inventory, confirm ownership, and make sure every included system, interface, and external dependency is understood before zone modelling begins.
That discipline matters because changes to the boundary can alter the outcome of the assessment. Adding or removing an interface may change the security level required for a zone, the treatment of a conduit, or the evidence needed to justify a control decision. In other words, SuC is a governance object as well as a technical one.
Practitioner note: if the SuC is vague, the rest of the IEC 62443-3-2 exercise will usually become harder to defend, not easier. Clear scoping is what makes the later risk decisions auditable and repeatable.
Standards & Framework Alignment
This section maps relevant standards and security frameworks to the operational risks and controls described in this guidance.
NIST SP 800-53 Rev 5 and CIS Controls v8 set the governance and control requirements practitioners need to meet.
| Framework | Control / Reference | Relevance |
|---|---|---|
| NIST SP 800-53 Rev 5 | SC-7 — Boundary Protection | SuC defines the assessment boundary that later drives network segmentation and conduit protection. |
| CM-8 — System Component Inventory | SuC depends on a complete asset inventory to state what is inside the assessed system. | |
| RA-3 — Risk Assessment | SuC is the defined subject of the cyber risk assessment process in IEC 62443-3-2. | |
| Recommendation — Define and enforce boundary protections around the scoped OT system and its trust interfaces. Maintain an authoritative inventory of all components included in the scoped system. Scope the risk assessment around the defined system boundary and its critical interfaces. | ||
| CIS Controls v8 | CIS-1 — Inventory and Control of Enterprise Assets | SuC requires a verified asset set before zones, conduits, and exposure can be assessed. |
| CIS-12 — Network Infrastructure Management | Zones and conduits turn the scoped OT boundary into a network control model. | |
| Recommendation — Inventory the assets inside the scoped system before assigning zones or controls. Map and manage network paths that connect the scoped zones and conduits. | ||
Related resources from NHI Mgmt Group
- Guide: OT and ICS Security Glossary
- How should teams prove an AI system was properly reviewed under the EU AI Act?
- What breaks when AI system inventory is incomplete under the EU AI Act?
- Who is accountable when a system is authorised under the NIST Risk Management Framework but later becomes noncompliant?
- What are the signs that a system prompt is failing under attack?
Deepen Your Knowledge
Free weekly newsletter
Subscribe to the NHI & AI Identity Journal
The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.
Bonus 33% off our NHI Course when you subscribe.
Reviewed and updated by the NHIMG editorial team on November 24, 2026.
NHI Mgmt Group — the #1 independent authority on Non-Human Identity, IAM, and Agentic AI security. nhimg.org