Impact is the ATT&CK for ICS tactic that describes the outcome of an attack on an industrial process: operators lose control or view, safety and protection fail, property is damaged, production stops or operational information is stolen. MITRE describes TA0105 as the adversary "trying to manipulate, interrupt, or destroy your ICS systems, data, and their surrounding environment". Its techniques are effects rather than actions, and MITRE itself notes that they "in and of themselves are not necessarily detectable", although the behaviour that leads to them can be mitigated and detected. That changes how defenders should use this tactic: it is the basis for consequence analysis, resilience design and incident response, not for a detection rule per technique. This hub covers all 12 techniques ATT&CK v20 lists under Impact, the real incidents ATT&CK maps to them, the mitigations MITRE assigns and how to plan, measure and recover. It is written for OT security leads, process safety and operations engineers, and incident responders, and builds on the MITRE ATT&CK for ICS Guide.

Key takeaways

  • Impact techniques are consequences. ATT&CK v20 detection strategies for all 12 techniques state that no standard detection method currently exists, so detection effort belongs on the techniques that lead to them.
  • IT incidents cause OT impact. Ransomware such as LockerGoga, Ryuk, EKANS and NotPetya appears under Loss of Productivity and Revenue (T0828) because unsegregated or dependent IT systems stopped production.
  • Loss of view and loss of control are the most recorded effects. In the v20 data T0828 has 10 recorded users, T0829 Loss of View 9, and T0826 Loss of Availability and T0827 Loss of Control 6 each.
  • Resilience mitigations dominate. Data Backup (M0953) is mapped to 8 of the 12 techniques, Out-of-Band Communications Channel (M0810) to 7 and Redundancy of Service (M0811) to 5.
  • Safety layers are the last line. For Damage to Property (T0879) and Loss of Safety (T0880), MITRE maps Safety Instrumented Systems (M0812) and Mechanical Protection Layers (M0805), which do not depend on the control network.

What Impact means on an industrial site

MITRE explains that Impact can be immediate disruption to the process and the operator, or longer-term damage, and that in some scenarios the process "can appear to function as expected" while it has been altered to serve the adversary over a longer period. It also notes that the adversary may use Impair Process Control (TA0106) and Inhibit Response Function (TA0107) techniques to produce and cover the impact. Three groups help when using the tactic for risk assessment:

  • Loss of operator capability: Denial of View (T0815), Loss of View (T0829), Denial of Control (T0813) and Loss of Control (T0827). "Denial" techniques are temporary, recovering once interference stops; "Loss" techniques are sustained and need hands-on intervention.
  • Integrity of the process: Manipulation of Control (T0831) and Manipulation of View (T0832), where the process or what operators see is altered, and Loss of Protection (T0837) and Loss of Safety (T0880), where the layers meant to catch faults are compromised.
  • Business and physical consequences: Loss of Availability (T0826), Loss of Productivity and Revenue (T0828), Damage to Property (T0879) and Theft of Operational Information (T0882).

MITRE describes T0828, T0882 and T0879 as encompassing the more granular goals of adversaries in targeted and untargeted attacks. For the techniques that typically produce these effects, see the ATT&CK for ICS Impair Process Control Tactic Guide and the ATT&CK for ICS Inhibit Response Function Tactic Guide.

Every technique in the tactic (ATT&CK v20)

The table lists all 12 techniques under TA0105 in ATT&CK v20, checked against the v20 STIX data and the live tactic page in November 2026. "Recorded users" is the number of groups, software and campaigns ATT&CK links to the technique.

IDTechniqueEffectRecorded usersExamples recorded by ATT&CK
T0879T0879 Damage to PropertyBreakdown or destruction of equipment, infrastructure and surroundings2Maroochy Water Breach, CyberAv3ngers
T0813T0813 Denial of ControlTemporary inability to adjust the process4Industroyer, 2015 Ukraine Electric Power Attack
T0815T0815 Denial of ViewTemporary loss of operator oversight2Industroyer, Maroochy Water Breach
T0826T0826 Loss of AvailabilityProducts or services cannot be delivered6FrostyGoop Incident, Unitronics Defacement Campaign, Conficker
T0827T0827 Loss of ControlSustained inability to command the process6LockerGoga, 2025 Poland Wiper Attacks, 2026 U.S. Water Utilities Attacks
T0828T0828 Loss of Productivity and RevenueProduction halts and financial loss, directly or via IT10NotPetya, EKANS, Ryuk, Triton Safety Instrumented System Attack
T0837T0837 Loss of ProtectionProtective functions such as relays fail to act on faults1Industroyer
T0880T0880 Loss of SafetySafety functions fail to bring the process to a safe state2Triton, CyberAv3ngers
T0829T0829 Loss of ViewSustained loss of reporting and visibility9KillDisk, Fuxnet, FrostyGoop Incident, LockerGoga
T0831Manipulation of ControlSet points, tags or commands altered3Stuxnet, Industroyer, 2015 Ukraine Electric Power Attack
T0832Manipulation of ViewOperators shown false process information2Stuxnet, Industroyer
T0882T0882 Theft of Operational InformationDesign documents, schedules and operational data taken5Duqu, Flame, ACAD/Medre.A, REvil, 2025 Poland Wiper Attacks

What real incidents show

NHI Mgmt Group counted the groups, software and campaigns in the ATT&CK for ICS v20 STIX data that have a "uses" relationship to any ICS technique (41, excluding revoked and deprecated objects). 23 of them are recorded with at least one Impact technique, more than for any other ICS tactic except Initial Access (25). Among those 23, the tactic used alongside Impact most often is Inhibit Response Function, followed by Initial Access, Impair Process Control and Lateral Movement. Several patterns stand out in the procedure records:

PatternCases in ATT&CKDefensive lesson
IT ransomware stops productionLockerGoga at Norsk Hydro (switch to manual operations), Ryuk (ERP server lost), EKANS (production loss at a manufacturing plant), NotPetya (vaccine production halted)Map OT dependencies on IT services and segment them; plan manual operations
Grid operators lose control and view2015 Ukraine Electric Power Attack (breakers opened via HMI, outages of around 6 hours), Industroyer (breakers toggled, serial channels blocked)Out-of-band communications and manual switching procedures
Credential lockout of exposed controllers2026 U.S. Water Utilities Attacks (passwords changed on internet-facing controllers), CyberAv3ngersRemove internet exposure, vault device credentials, keep recovery access
Wiping of field and HMI devices2025 Poland Wiper Attacks (RTUs, protection relays and HMIs damaged), KillDiskOffline backups of configuration and firmware, spares, rebuild playbooks
Process and view manipulationStuxnet (PLC parameters changed while recorded I/O values were replayed), FrostyGoop Incident (parameters changed, heating lost)Independent physical measurements and safety layers that do not trust the HMI
Safety system targetingTriton (SIS logic reprogrammable to let unsafe conditions persist; a controller tripped to a failed safe state halted the plant for more than a week)Isolated SIS, run mode keyswitches, mechanical protection

The technique descriptions also cite the 2021 Colonial Pipeline ransomware incident, where pipeline operations were halted from 7 May until 12 May, and a targeted attack on a German steel mill reported by the BSI in its 2014 IT Security Report, where control system breakdowns led to the uncontrolled shutdown of a blast furnace. See the ICS Malware History Guide.

Mitigations MITRE maps across the tactic

The mitigation relationships for Impact are almost entirely about resilience and independence, because by the time an effect occurs, prevention has already failed. The counts are the number of Impact techniques each mitigation is mapped to in v20.

MitigationTechniques (count)What it looks like on site
M0953 Data BackupT0813, T0815, T0826, T0827, T0828, T0829, T0831, T0832 (8)Offline, tested copies of controller programs, HMI projects, historian configuration and firmware. See the OT Backup, Recovery and Golden Image Guide
M0810 Out-of-Band Communications ChannelT0813, T0815, T0826, T0827, T0829, T0831, T0832 (7)A second path for commands and status, such as radio, telephone or hardwired panels, that does not share the compromised network
M0811 Redundancy of ServiceT0813, T0815, T0826, T0827, T0829 (5)Hot standby controllers, redundant HMI and SCADA servers, alternative data paths
M0802 Communication AuthenticityT0831, T0832 (2)Authenticated command and reporting messages so spoofed commands or values are rejected
M0812 Safety Instrumented SystemsT0879, T0880 (2)Independent SIS that trips the process to a safe state. See the Safety Instrumented Systems Security Guide
M0805 Mechanical Protection LayersT0879, T0880 (2)Relief valves, rupture discs, overspeed trips and other physical protections that no software can override
M0807 Network AllowlistsT0879 (1)Only approved hosts can send commands to controllers
M0809 Operational Information Confidentiality, M0922 Restrict File and Directory Permissions, M0803 Data Loss Prevention, M0941 Encrypt Sensitive InformationT0882 (1 each)Classified and restricted design documents, outbound data controls and encrypted storage

MITRE maps no mitigation to Loss of Protection (T0837) in v20. In practice the controls for it are those that protect relays and protection devices from the techniques that cause the loss, covered under Inhibit Response Function.

Detection and measurement

Since there is no standard detection for the effects themselves, the job splits in two: detect the precursor techniques, and recognise impact quickly when it happens so that response starts in minutes.

EffectPrecursors to detectHow the effect shows up
Loss or denial of view (T0829, T0815)Block Communications (T1695), Block Operational Technology Message (T1691), Service Stop (T0881), firmware changes (T1693)Stale values on HMIs, historian gaps, devices going silent, communication alarms
Loss or denial of control (T0827, T0813)Change Credential (T0892), wipers on HMIs, serial gateway changesCommands not acknowledged, operator lockout, failed logins on controllers
Manipulation of control or view (T0831, T0832)Unauthorized Message (T1692), Modify Program (T0889), Manipulate I/O Image (T0835)Disagreement between HMI values and independent field measurements; set point changes without operator action
Loss of protection or safety (T0837, T0880)Writes to relays or SIS, Change Operating Mode (T0858), Modify Alarm Settings (T0838)Protection or SIS diagnostics, controllers leaving run mode, SIS trips
Theft of operational information (T0882)Program Upload (T0845), Data from Information Repositories (T0811)Large outbound transfers from engineering stores
Loss of availability or productivity (T0826, T0828)Ransomware on IT and OT hosts, Data Destruction (T0809)Encryption alerts, production KPIs falling, planned manual fallback invoked

Linked technique pages carry the detection detail for precursors, for example T1695 Block Communications, T0892 Change Credential and T1692 Unauthorized Message.

Metrics that show resilience:

  • Percentage of critical controllers and HMIs with an offline backup restored successfully in the last 12 months.
  • Time to restore a controller program and HMI project from backup in a drill, against the recovery time objective.
  • Percentage of critical processes with a documented and rehearsed manual operating procedure.
  • Percentage of critical alarms and commands with an out-of-band path.
  • Number of OT functions with an undocumented dependency on IT services such as Active Directory, ERP or licence servers (target zero).
  • Time from a simulated loss of view to the incident being declared.

Where identity fits

Several of the clearest Impact cases are identity failures. ATT&CK records that in the 2026 U.S. Water Utilities Attacks the adversary changed passwords on internet-facing controllers, locking out operators and causing loss of control and view, and that CyberAv3ngers locked victims out by changing PLC management passwords.

  • Device credentials: unique per device, vaulted, with a tested recovery method, so a password change does not become a sustained Loss of Control.
  • Shared dependencies: when HMIs authenticate against the corporate directory, a directory outage or ransomware event can cause Loss of View. Keep local break-glass accounts for operator stations.
  • Remote access identities: vendor and remote engineering accounts are frequent paths to controllers. See the OT and ICS Identity and Access Guide and the OT Remote Access Guide.

Planning for Impact

  1. Run a consequence analysis: for each critical process, walk through the 12 Impact techniques and record the worst credible outcome, the safety layers that would stop it and how long the business can tolerate it.
  2. Map dependencies: list every IT service the OT environment needs to keep running. LockerGoga, Ryuk and NotPetya cases show that the impact often comes from these.
  3. Build independence: SIS and mechanical protection that do not rely on the control network; out-of-band paths for critical alarms and commands.
  4. Back up and test restores: offline copies of programs, configurations, firmware and HMI projects, with restore drills on a test bench before relying on them in production.
  5. Write and rehearse manual operations: agree with operations when to fall back to manual control and how to return to automatic, including the checks needed before reconnecting systems.
  6. Prepare the response: OT incident playbooks for each effect, with decision points owned by operations and safety, not only security. See the OT Incident Response Guide.

Decision guidance: small sites usually cannot afford redundant servers everywhere, so prioritise offline backups, manual procedures and mechanical protection, which give the most resilience for the cost. Large operators should use the technique table as a common consequence taxonomy across sites and fund redundancy and out-of-band paths where the tolerable outage is shortest. Where an effect such as Loss of Safety could harm people, independent engineering safeguards take priority over any cyber control.

Framework mapping

DefenceNIST SP 800-53 Rev. 5NIST CSF 2.0ATT&CK for ICS mitigation
Backup and restore of OT configurationCP-9, CP-10PR.DS-11, RC.RP-03M0953
Redundancy and alternative communicationsCP-8, SC-36PR.IR-03M0811, M0810
Contingency and manual operations planningCP-2, CP-4ID.IM-04M0810, M0811
Authenticated commands and reportsSC-8, SI-10PR.DS-02M0802
Fail-safe designSC-24PR.IR-03M0812, M0805
Protection of operational informationAC-3, SC-28PR.DS-01M0809, M0941, M0922, M0803
Incident response for OT effectsIR-4, IR-8RS.MA-01Not a mitigation in ATT&CK

See the NIST SP 800-82 OT Security Guide and the IEC 62443 Guide.

Common failure patterns

  • Writing detection rules for the effect: by the time Loss of Control is visible, the attack has succeeded. Effort belongs on precursors and on fast recognition.
  • Untested backups: controller backups that have never been restored, or that are stored on the engineering workstation a wiper will destroy.
  • Hidden IT dependencies: HMIs that need domain authentication or a licence server, so an IT incident becomes an OT outage.
  • Trusting the HMI during an incident: manipulation of view means the screen may be wrong. Responders need independent measurements and local gauges.
  • Internet-exposed controllers with default or shared passwords: the pattern behind the recorded water sector lockouts.
  • Manual procedures nobody has practised: Norsk Hydro could switch many sites to manual operation; many organisations would find their procedures out of date.

Practitioner checklist

  • A consequence analysis covers each Impact technique for every critical process.
  • Offline backups of programs, firmware and HMI projects are restored in a drill at least yearly.
  • Critical alarms and commands have an out-of-band path.
  • SIS and mechanical protection are independent of the control network.
  • OT dependencies on IT services are documented and minimised.
  • Device credentials are vaulted with tested recovery, and no controller is reachable from the internet.
  • Manual operating procedures are current and rehearsed with operations.
  • Detection covers the precursor techniques linked above, using ATT&CK v20 IDs.
  • OT incident playbooks name operations and safety decision owners for each effect.

Standards and references

Related NHI Mgmt Group resources: MITRE ATT&CK for ICS Guide · OT Backup, Recovery and Golden Image Guide · OT Incident Response Guide · Safety Instrumented Systems Security Guide

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

NHIMG Editorial Note
Researched and written by the NHI Mgmt Group editorial team using AI tools, under the editorial direction of Lalit Choda. Facts are drawn from the sources listed on this page and checked by our automated quality process. Last updated 12 November 2026. Spotted an error? Use our contact page.
NHI Mgmt Group, the independent authority on Non-Human Identity, IAM and Agentic AI security. nhimg.org