Network diagrams describe the cabling someone intended, while the patch panel shows what is actually plugged in, and an undocumented cable or device is invisible to every logical control. MITRE D3FEND names the countermeasure Direct Physical Link Mapping (D3-DPLM), with the synonym Manual Physical Link Mapping, and defines it as creating "a physical link map by direct observation and recording of the physical network links." It sits under the Model tactic as a child of Physical Link Mapping (D3-PLM), alongside Active Physical Link Mapping (D3-APLM). This page covers when inspection is the right method, what to record, how to run a walkdown and keep the record current, and how it supports detection and physical hardening. It is written for network engineers, data centre and OT site teams, and auditors who need evidence that physical topology records are accurate.

Key takeaways

  • It is the fallback, and sometimes the only option. D3FEND recommends automated active physical link mapping where feasible, and physical inspection where it is not, because passive traffic monitoring cannot reliably map physical links.
  • Inspection finds what protocols cannot. Unmanaged switches, media converters, taps, serial links, out-of-band modems and devices that do not speak discovery protocols only show up when someone looks.
  • The record must be structured. Port-to-port connections with identifiers, cable labels, rack positions and dates make the map comparable with automated discovery and with the previous walkdown.
  • Differences are the security signal. A new device, a moved cable or a link that discovery protocols cannot see is a finding to investigate, not just a documentation fix.
  • D3FEND's ATT&CK relations here are weak. D3FEND lists only inferred, experimental relations through shared artefacts; the real value is accurate topology for segmentation, incident response and physical access control.

D3-DPLM at a glance

AttributeValue
D3FEND IDD3-DPLM (d3f:DirectPhysicalLinkMapping)
TacticModel
Parent techniquePhysical Link Mapping (D3-PLM), defined as identifying and modelling "the link connectivity of the network devices within a physical network"; itself a child of Network Mapping
SynonymManual Physical Link Mapping
Digital artefacts (from parent)Network Node and Physical Link (D3FEND relation: maps)
D3FEND referenceNetwork mapping article (Wikipedia)
ATT&CK relationsInferred and experimental only (D3FEND 1.6.0, checked November 2026)
EffortHigh per site; scales with port count and how well cabling is labelled

When to use inspection instead of discovery

D3FEND's own considerations state that building and maintaining physical topologies by hand is challenging and time-consuming for large networks, so automated active mapping should be considered as a partial or complete solution. Active mapping relies on devices reporting their neighbours, typically through the Link Layer Discovery Protocol defined in IEEE 802.1AB, which provides managed objects for discovering physical topology from adjacent stations. The table shows where each method fits.

SituationActive mapping (D3-APLM)Direct inspection (D3-DPLM)
Managed enterprise switching with LLDP enabledPrimary methodSpot checks to validate the automated map
Unmanaged switches, hubs, media convertersNot visible as neighboursRequired
OT and industrial networks where probing is restrictedOften limited by operational risk policyPrimary method, combined with passive monitoring for logical links
Serial, fieldbus and non-Ethernet linksOut of scope for 802 LAN discoveryRequired
Out-of-band links (console servers, cellular modems, management ports)PartialRequired to find undocumented ones
Data centre build, move or decommissionConfirms the resultRequired for acceptance and handover
Suspected rogue device or physical tapMay miss passive or unmanaged devicesRequired

See D3-APLM Active Physical Link Mapping for the automated method.

What to record

A physical link record that cannot be compared with anything is a drawing. The fields below are an NHI Mgmt Group suggestion for a record that can be reconciled against automated discovery and the asset inventory.

FieldExampleUse
Site, room, rack and positionDC1, Hall B, rack B07, U22Locates the device for response and physical access control
Device A and portAccess switch asset tag and interface nameJoins to the network node inventory
Device B and portServer NIC, patch panel port or field deviceDefines the link end to end
Cable identifier and mediaCable label, copper or fibre type, lengthTraces intermediate patching
Intermediate passive pointsPatch panels, cross-connects, splice traysShows where a tap or reroute could sit
Observed stateLink light, unlabelled, unknown device attachedCaptures findings for follow-up
Observer and dateEngineer name, walkdown date, photo referenceEvidence for audit and comparison

The ANSI/TIA-606 administration standard family is the usual reference for labelling and record keeping in structured cabling; use the identifier scheme your cabling contractor already follows rather than inventing a second one.

How to run a walkdown

  1. Prepare from what you already know. Export the current automated neighbour map, the network node inventory and the last walkdown record for the site, so the team checks differences rather than starting blank.
  2. Agree safety and access. Book escorted access, agree a no-touch rule for live equipment unless a change is approved, and for OT sites follow the site's operational safety process.
  3. Record port by port. Work rack by rack, recording both ends of each cable, the labels and any device not in the inventory. Photograph panels as evidence.
  4. Trace unknowns, do not unplug them. An unknown device or cable is raised as a finding and investigated through change and incident processes. Removing it on the spot destroys evidence and may cause an outage.
  5. Reconcile and publish. Load the record into the network source of truth or CMDB, compare it with automated discovery, and open tickets for every mismatch.
  6. Set the next cycle. Schedule walkdowns by risk (for example, critical rooms and OT cells more often than branch closets; an NHI Mgmt Group suggestion, not a standard) and trigger extra walkdowns after major moves or incidents.

How it supports detection and hardening

D3-DPLM is a Model technique: it detects nothing in real time. These connections are NHI Mgmt Group's view of how the map is used, not D3FEND relations.

  • Rogue device detection: a verified port map makes unexpected link-up events and new MAC addresses on a port meaningful, because the expected attachment is known.
  • Segmentation assurance: physical bypasses such as a cable bridging two segments or a dual-homed device defeat logical segmentation. See the OT Network Segmentation, Purdue Model and IEC 62443 Zones and Conduits Guide.
  • Physical access control: knowing which rooms and panels carry sensitive links tells you where NIST SP 800-53 PE-4 Access Control for Transmission controls belong. See the Physical Security Guide for Security Teams.
  • Incident response: responders isolating a compromised host need to know which switch port and which physical path to cut, which is often the slowest part of OT containment.

ATT&CK techniques D3FEND relates to D3-DPLM

Relationship type: inferred only. D3FEND shows no direct ATT&CK mapping for D3-DPLM. It lists a small set of inferred, experimental relations through shared artefacts. They are shown for completeness; none of them is detected by a physical link map. Each ID was checked against ATT&CK v20.

ATT&CK IDTechniquePractical relevance
T1505.002, T1505.003Server Software Component: Transport Agent, Web ShellNone direct; the map only locates the affected server
T1114.002Remote Email CollectionNone direct
T1578.002, T1578.003, T1578.004Create, Delete and Revert Cloud InstanceNone direct; cloud instances have no physical links the customer can inspect
T1686.002Disable or Modify System Firewall: Network Device FirewallLimited: a verified map shows which network devices enforce boundaries. D3FEND lists this under an ATT&CK ID revoked in v20; T1686.002 is the v20 successor

How to verify it works

MetricExample target (NHI Mgmt Group suggestion, not a standard)What it shows
Ports in scope with a recorded link in the last cycle100% for critical rooms and OT cellsCoverage
Agreement between walkdown and automated neighbour dataAbove 98% where both existAccuracy of both methods
Unknown devices found per walkdownFalling over time, each one resolvedChange control discipline
Mismatch tickets closed within the agreed periodAbove 90%Findings are acted on
Time to identify the physical port of a given host during an exerciseMinutes, not hoursUsefulness for response

Limits and failure patterns

  • A one-off project: a walkdown done for a migration and never repeated is out of date within months; schedule cycles and tie updates to change control.
  • Drawings instead of records: diagrams cannot be reconciled automatically. Keep port-level records and generate diagrams from them.
  • Trusting labels: labels survive moves that cables do not. Trace both ends on critical links rather than reading the label alone.
  • Ignoring out-of-band paths: console servers, management networks and cellular modems give remote access that bypasses the production network and its monitoring.
  • Unplugging during the walkdown: removing unknown equipment on sight loses evidence and can stop production, especially in OT.

Framework mapping

FrameworkReferenceRelevance
NIST CSF 2.0ID.AM-01Inventories of hardware managed by the organisation are maintained
NIST CSF 2.0ID.AM-03Representations of authorised network communication and data flows are maintained
NIST SP 800-53 Rev 5CM-8 System Component InventoryAccurate component inventory that the link map joins to
NIST SP 800-53 Rev 5PE-4 Access Control for TransmissionPhysical protection of transmission lines inside facilities
CIS Controls v8.1Safeguard 12.4 Establish and Maintain Architecture Diagram(s)Network architecture documentation
MITRE D3FENDD3-PLM, D3-DPLMParent and technique

Practitioner checklist

  • Use active mapping where devices support it and reserve walkdowns for what it cannot see.
  • Record links port to port with device identifiers, cable labels, rack positions, observer and date.
  • Start every walkdown from the automated map and the last record, and check differences.
  • Raise unknown devices and cables as findings; never unplug them during the walkdown.
  • Include out-of-band, serial and management links in scope.
  • Load records into the network source of truth and reconcile with discovery data.
  • Schedule walkdowns by risk and after major moves or incidents.

Standards and references

Related NHI Mgmt Group resources: MITRE D3FEND Network Mapping Implementation Guide · D3-PLM Physical Link Mapping · OT Asset Visibility Guide · Data Centre Security Guide · MITRE D3FEND Guide

PDF for subscribers

Take this guide with you

Every section, table and checklist in one PDF, with links to the sources and related guides. Subscribe to our weekly NHI & AI Identity Journal and we’ll email you a download link.

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

NHIMG Editorial Note
Researched and written by the NHI Mgmt Group editorial team using AI tools, under the editorial direction of Lalit Choda. Facts are drawn from the sources listed on this page and checked by our automated quality process. Last updated 12 November 2026. Spotted an error? Use our contact page.
NHI Mgmt Group, the independent authority on Non-Human Identity, IAM and Agentic AI security. nhimg.org

PDF Downloads for Newsletter Subscribers

Get the guide

Enter your details and we’ll email you a download link.

The full guide is free to read online. The PDF is a thank you for subscribing.

Fill in all fields marked * and tick the PDF box to continue.