Most organisations depend on satellite time and position in places nobody has written down, so a GNSS outage or spoofing event finds the dependencies for them. This guide sets out how to run a positioning, navigation and timing (PNT) resilience programme: find every system that consumes GNSS-derived time or position, decide how long each can run without it, choose holdover and alternative sources to match, and test and monitor the result. It is written for infrastructure, OT and resilience leads in sectors such as energy, telecoms, finance, transport and data centres. How jamming and spoofing work and how to detect them is covered in the GNSS Spoofing and Jamming Guide; this page is the programme around it. Policy documents referenced were checked in November 2026 and policy in this area changes, so confirm current versions before relying on them.
Key takeaways
- Inventory first: NIST IR 8323r1 starts with documenting GNSS receivers, NTP and PTP servers, clocks and the software that relies on distributed time; you cannot size holdover for systems you have not found.
- Holdover is a requirement, not a datasheet figure: set a required duration and accuracy per system, approved by its owner, and prove it with the antenna disconnected.
- Diversity beats redundancy: two receivers on one antenna fail together; the DHS conformance framework reserves its top level for diversity of PNT source technology to defeat common mode threats.
- Monitoring is cheap and early: receiver alarms, position-hold changes, carrier-to-noise drops and disagreements between time sources show interference before outputs go wrong.
- Treat it as a programme: ownership, a maturity target, supplier requirements and annual testing keep resilience from decaying as equipment is replaced.
What PNT dependency looks like
The UK Government's PNT overview states that the UK's PNT is almost completely provided through GNSS, primarily GPS, and cites a 2023 estimate that losing GNSS for 24 hours would cost the economy £1.42 billion. The dependency is mostly invisible because it arrives as time. A GNSS timing receiver on a roof disciplines a grandmaster clock, which feeds PTP to substations or base stations and NTP to servers, which stamp logs, transactions and authentication tokens. Position dependencies are more obvious (fleet tracking, vessel navigation, survey) but often sit with operations rather than security.
Three properties make the risk different from other outages:
- Silent failure: a spoofed receiver keeps reporting a valid lock while drifting, so downstream systems continue with wrong time rather than stopping.
- Common mode: one jammer near a site, or one constellation-wide fault, affects every receiver in range at once.
- Recovery effects: a time step when the source returns can break certificate checks, log ordering and protection schemes, so recovery needs its own plan.
Time also underpins identity. Kerberos, TOTP codes, signed tokens and certificate validity all compare clocks, so a large time error can cause authentication failures or accept expired credentials. The NTP Security Guide covers the network time layer.
Mapping timing and position dependencies
NIST IR 8323 Revision 1 (Foundational PNT Profile, January 2023, written in response to Executive Order 13905) frames the inventory as asset management: document PNT components and provider interfaces, identify software that relies on distributed time such as NTP and PTP, document data sources and distribution media, and catalogue external PNT connections. The DHS and CISA Best Practices for Resilient PNT Supporting Critical Infrastructure (September 2024) adds documenting expected performance when external sources are unavailable and reducing reliance on external sources where a local clock would do.
Build the map as a table that each system owner completes and signs:
| Field | What to record | Example |
|---|---|---|
| System and owner | Business service, asset ID, accountable owner | Substation protection relays, grid operations |
| PNT use | Time of day, frequency, phase, position, or a combination | Phase and time of day for synchrophasors |
| Source chain | Antenna, receiver, grandmaster or server, distribution protocol, clients | Roof antenna, GNSS receiver, PTP grandmaster, PTP to relays |
| Accuracy requirement | Maximum tolerable error against UTC or between nodes | Microseconds between relays |
| Required holdover | How long the system must stay within requirement with GNSS lost | Set by owner, for example 72 hours |
| Current fallback | Holdover oscillator, second source, manual procedure, none | Rubidium in grandmaster, no second source |
| Impact if wrong or lost | Safety, service, regulatory, financial | Protection mis-operation, regulatory incident |
| Supplier dependency | Carrier or provider timing services and their stated guarantees | Carrier-delivered frequency reference |
Practical sources for finding hidden receivers: purchase records for timing and GNSS equipment, NTP and PTP server configuration (which upstream each server trusts), roof surveys for antennas, and asking OT vendors which embedded devices contain receivers. CISA's Time Guidance for Network Operators, CIOs and CISOs recommends adding GPS receivers to the standard IT inventory and applying firmware updates as the manufacturer advises. For OT estates, record PNT fields in the OT Asset Register Template.
Holdover and oscillator options
Holdover is the period a clock keeps acceptable time after losing its reference. CISA's time guidance defines it as oscillator performance when synchronisation is lost, and asks whether you have set a holdover time for each time-reliant system and had end users approve it. The DHS and CISA 2024 best practices note that holdover performance depends on the clock's state when the reference is lost, the length of the event and the quality of the oscillator, and give an example that for many GPS use cases an independent clock is enough if interference can be removed within three days.
| Oscillator class | Relative holdover | Trade-offs | Typical fit |
|---|---|---|---|
| Quartz (TCXO) | Shortest | Low cost and power; drifts quickly with temperature | Edge devices with loose accuracy needs |
| Oven-controlled quartz (OCXO) | Longer than TCXO; typically hours at tight tolerances | Moderate cost; warm-up time; ageing | Most enterprise grandmasters and NTP appliances |
| Rubidium | Days | Higher cost; DHS notes it can take several days to settle to specification after start-up | Telecoms, utilities, data centres needing multi-day holdover |
| Caesium beam | Longest; a primary frequency reference | Highest cost; DHS 2015 guidance cites tube lifetimes of 5 to 12 years and periodic calibration | National or regional timing hubs, carrier cores |
Vendor holdover figures assume a stable temperature and a fully settled oscillator. Write the requirement as "within X microseconds of UTC for Y hours" and verify it in a test (see Testing and monitoring). Enhanced primary reference time clocks, specified in ITU-T G.8272.1, combine GNSS with a caesium-class ensemble for long autonomous holdover in telecoms networks; consider them only where the dependency map shows multi-day, tight-tolerance needs.
Decision guidance: a small organisation whose only dependency is server and log time can usually rely on OCXO holdover in an NTP appliance plus diverse network time sources. Operators of protection systems, mobile networks or trading platforms with microsecond requirements need rubidium or better at each timing site, plus an independent terrestrial source.
Alternative timing sources
Holdover buys time; alternative sources remove the deadline. The 2024 DHS and CISA best practices call for dissimilar or redundant sources checked for common-mode failures, multiple GNSS bands and constellations where the benefit justifies the cost, and at least two NTP servers from the lowest possible stratum, with more than three strongly recommended.
| Source | What it provides | Strengths | Limits |
|---|---|---|---|
| Multi-constellation, multi-band GNSS | Time and position | Better resistance to single-system faults and some interference | Same radio band family; a broadband jammer still defeats it |
| PTP over dedicated fibre | Time, phase and frequency from a remote reference | Independent of radio; sub-microsecond possible on private networks | Needs PTP-aware network or dedicated fibre; asymmetry must be calibrated |
| Traceable NTP over private or public networks | Time of day | Cheap, ubiquitous; CISA notes it suits needs that do not require GPS-level accuracy | Millisecond-class over the internet; must be authenticated (NTS) |
| Carrier-delivered timing or frequency | Frequency or time from a provider's core | Offloads engineering; can be diverse from your own GNSS | Check whether the provider's own reference is GNSS; capture guarantees in contract |
| Long-wave time signals (for example MSF, WWVB) | Time of day | Independent of GNSS; low-cost receivers | Low accuracy; coverage and maintenance outages |
| eLoran, where available | Terrestrial time and position | High-power, hard to jam at range; dissimilar from GNSS | Not generally available; the UK framework commits to developing a proposal for a sovereign eLoran system |
| Inertial and local sensors | Position continuity | Bridges short positioning gaps | Drifts over time; position only |
PTP security, profiles and grandmaster protection are covered in the IEEE 1588 PTP Time Synchronisation Security Guide. Whatever the mix, the timing equipment should compare sources and refuse one that disagrees with the others, rather than simply failing over to whichever is available.
Where identity fits
Timing servers, grandmasters and receivers are managed devices with web interfaces, SNMP communities and service accounts. An attacker with administrative access can change the reference or the time directly, which defeats every radio-layer defence. Remove default credentials, put management interfaces behind a privileged access path, and use authenticated time (NTS for NTP, PTP security mechanisms where supported). See the IEC 62443-3-3 and 4-2 Security Levels Guide for component requirements in OT.
Testing and monitoring
Implement in phases:
- Baseline: complete the dependency map, record current fallback for each system and score each against a target level (below).
- Quick wins: add receiver alarms and time-offset monitoring to the SOC or NOC; reposition or protect antennas. The 2024 best practices recommend antennas more than 10 m from and slightly above nearby structures and a clear sky view of at least plus or minus 30 degrees around vertical for stationary timing.
- Lab or shielded test: validate holdover by disconnecting the antenna or using a GNSS simulator in a shielded environment, measuring offset against an independent reference over the required duration. NIST IR 8323r1 lists PNT signal simulation to assess susceptibility.
- Pilot site: add an alternative source at one critical site, run it in monitor-only mode first, then enable source comparison and automatic selection.
- Roll out by criticality: extend to other sites in order of impact, keeping configuration backups so a change can be reverted if a new source causes instability.
- Recovery test: rehearse the return of GNSS. The 2024 best practices advise delaying reacquisition after interference clears and limiting the search range, so outputs do not jump.
Monitor continuously: receiver alarms and fault indications, changes to a fixed receiver's computed position against its surveyed location, carrier-to-noise and RF power changes, reference source switching, and offset between independent time sources. CISA's Epsilon algorithm suite flags inconsistencies in GPS receiver position, velocity and clock data for basic spoofing detection without receiver changes. Test annually and before known events such as leap seconds and GPS week rollover, as both CISA and NIST advise.
Metrics:
- Dependency map coverage: percentage of time-reliant systems with a signed map entry.
- Holdover verified: percentage of critical systems whose holdover was tested in the last 12 months and met requirement.
- Source diversity: percentage of critical sites with at least one non-GNSS timing source.
- Time-offset alerts: count and mean time to investigate alerts where sources disagree beyond threshold.
- Interference events: detected jamming or spoofing events per quarter, and the share reported to the relevant authority.
Governance and programme roadmap
The DHS Resilient PNT Conformance Framework (version 1.0, developed in 2019 and 2020; CISA now lists a version 2.0) gives a useful target scale for each system. Its levels are cumulative:
| Level | What it means | Added requirement |
|---|---|---|
| 0 | Non-resilient | May accept unverified input; recovery may need manual intervention or replacement |
| 1 | Recovers after the threat is removed | Verify stored data, full manual recovery, secure firmware reload |
| 2 | Keeps a solution during the threat, degradation may be unbounded | Identify and exclude compromised sources; automatic recovery of individual sources |
| 3 | Keeps a solution with bounded degradation | Corruption cannot spread between sources; cross-verify all sources |
| 4 | Keeps a solution without degradation | Diversity of PNT source technology against common mode threats |
Set a target level per system from its impact, then use the gap to drive the roadmap. Governance elements:
- Ownership: one accountable PNT resilience owner, with system owners responsible for their map entries and holdover sign-off.
- Policy context: in the US, EO 13905 (February 2020) drove the NIST profile and the DHS framework, and CISA advises critical infrastructure to assess PNT dependencies and set resilience requirements. In the UK, the Government Framework for Greater PNT Resilience (October 2023) remains in place, a National PNT Office sits in the Department for Science, Innovation and Technology, and the Royal Institute of Navigation launched best practice principles and a checklist for businesses on 20 November 2024.
- Procurement: require suppliers of timing equipment and timing services to state holdover performance, source diversity, anti-spoof capability and firmware support periods, and to report interference events.
- Continuity planning: add GNSS loss as a scenario in business continuity and incident response plans, with the recovery steps above. See the Business Continuity and Disaster Recovery Guide.
- Reporting: establish contacts with national authorities and report detected interference, as the 2024 best practices recommend.
Framework mapping
| Framework | Reference | Programme element |
|---|---|---|
| NIST CSF 2.0 | ID.AM-01, ID.AM-03, ID.AM-04 | Inventory of receivers and clocks, timing data flows, supplier timing services |
| NIST CSF 2.0 | PR.IR-03 | Holdover and alternative sources meet resilience requirements |
| NIST CSF 2.0 | DE.CM-01, DE.CM-09 | Monitoring receivers and time offsets for adverse events |
| NIST SP 800-53 Rev 5 | SC-45, SC-45(1), SC-45(2) | System time synchronisation with authoritative and secondary authoritative sources |
| NIST SP 800-53 Rev 5 | CP-2, CP-8, SA-9 | Contingency planning, telecoms services, external timing services |
| NIST IR 8323r1 | Foundational PNT Profile (CSF 1.1 based) | Sector-neutral PNT risk management baseline |
Common failure patterns
- Two receivers, one antenna: redundancy that shares a feed, a cable run or a roof position fails as one.
- Holdover quoted, never tested: the datasheet figure assumed a settled oscillator; a rubidium unit replaced last week has not settled.
- Failover without comparison: equipment switches to whatever source is present, including a spoofed one, instead of rejecting a source that disagrees.
- Carrier time assumed independent: the "backup" service is disciplined by the same GNSS constellation upstream.
- No recovery plan: GNSS returns, clocks step, and certificate checks, logs and protection schemes misbehave.
- Exposed management interfaces: default passwords on a timing appliance let anyone change time without touching the radio layer.
Practitioner checklist
- Name an accountable PNT resilience owner and system owners for every time-reliant service.
- Complete and sign the dependency map, including embedded receivers in OT and supplier timing services.
- Set a required accuracy and holdover duration per system, approved by its owner.
- Test holdover with GNSS disconnected or simulated in a shielded environment, at least yearly.
- Give each critical site at least one non-GNSS timing source and enable source comparison.
- Route receiver alarms, position-hold changes and time-offset alerts to the SOC or NOC.
- Harden timing device management: unique credentials, privileged access path, authenticated time protocols.
- Add GNSS loss and recovery to continuity plans and exercise it.
- Write holdover, diversity and anti-spoof requirements into timing procurement.
- Track the five metrics above and review the target levels annually.
Standards and references
- NIST: IR 8323 Rev. 1 Foundational PNT Profile
- DHS S&T and CISA: Best Practices for Resilient PNT Supporting Critical Infrastructure
- DHS S&T: Resilient PNT Conformance Framework
- CISA: Time Guidance for Network Operators, CIOs and CISOs
- DHS: Best Practices for Improved Robustness of Time and Frequency Sources in Fixed Locations
- CISA: Positioning, Navigation and Timing
- UK Government: Positioning, navigation and timing overview
- ITU-T: G.8272.1 Timing characteristics of enhanced primary reference time clocks
Related NHI Mgmt Group resources: GNSS Spoofing and Jamming Guide · IEEE 1588 PTP Time Synchronisation Security Guide · NTP Security Guide · Business Continuity and Disaster Recovery Guide