Most OT security guidance tells engineers what controls to buy, but the hardest OT decisions are judgement calls made under pressure: whether to pay, whether to restore, whether to send people to site, whether to connect a new supplier. In October 2024 the Australian Signals Directorate's Australian Cyber Security Centre (ASD's ACSC) published Principles of operational technology cyber security, co-sealed by agencies from the United States, United Kingdom, Canada, New Zealand, Germany, the Netherlands, Japan and the Republic of Korea. This guide takes each principle, turns it into the questions you should be able to answer, and shows how it maps to ISA/IEC 62443, NIST SP 800-82 and NIST CSF 2.0. It is written for OT asset owners, control engineers and CISOs with OT responsibility; for the wider programme see the OT Security Guide.
Key takeaways
- Six principles, one purpose: the guidance is a decision aid, not a control catalogue, and it is aimed at everyone who makes OT decisions, from executives to operational staff.
- Safety comes first in every call: threats to life, plant, environment and reliability shape choices such as ransom payment, backup restoration and whether active asset discovery is acceptable.
- Know the minimum that must keep running: top-down and bottom-up analysis of vital systems tells you what to defend hardest and what can be sacrificed during containment.
- OT data and the supply chain are attack surface: engineering drawings, PLC logic and vendor laptops give adversaries long-lasting advantage, so they need the same protection as the plant itself.
- Separation and people close the loop: segment OT from IT and from other organisations, never manage critical systems from less critical ones, and train operators to consider a cyber cause before they reboot or reflash.
Where the principles come from
The document was authored by ASD's ACSC and co-sealed by CISA, NSA, FBI and MS-ISAC in the United States, NCSC-UK, the Canadian Centre for Cyber Security, NCSC-NZ, Germany's BSI, NCSC-NL, Japan's NISC and National Police Agency, and the Republic of Korea's NIS and National Cyber Security Center. NCSC-NZ announced it on 4 October 2024. Its stated audience is OT decision makers across the organisation, including board members making strategic choices and technical staff making day-to-day ones.
It sits alongside, not instead of, the established standards. ISA/IEC 62443 gives the programme, risk assessment and technical requirements (see the IEC 62443 Guide). NIST SP 800-82 Rev. 3, Guide to Operational Technology (OT) Security, published in September 2023, gives architecture and countermeasures (see the NIST SP 800-82 OT Security Guide); as of November 2026 NIST has an initial public draft of Revision 4 open for comment.
| # | Principle (name as published) | The practical question it asks |
|---|---|---|
| 1 | Safety is paramount | Could this decision, control or recovery step put people, plant, environment or reliability at risk? |
| 2 | Knowledge of the business is crucial | Which systems are vital to the critical service, what do they depend on, and who understands them? |
| 3 | OT data is extremely valuable and needs to be protected | Where do our drawings, logic, configurations and logs live, and who outside OT holds copies? |
| 4 | Segment and segregate OT from all other networks | Is OT separated from the internet, from IT, from other organisations and from its own less critical zones? |
| 5 | The supply chain must be secure | Do we know the provenance and behaviour of every device, laptop and vendor that touches OT? |
| 6 | People are essential for OT cyber security | Do operators, engineers and field staff have the skills, culture and permission to spot and report a cyber cause? |
Principle 1 to 6 in practice
1. Safety is paramount
Cyber-physical systems carry hazards that IT does not: high voltage, pressure release, explosion, kinetic impact and chemical or biological release. The guidance asks leaders to weigh three safety areas in every decision: human life, plant and environment, and reliability and uptime. It also asks that OT cyber controls be deterministic, predictable and, where needed, black-start compliant.
- Ransom: the guidance treats payment as generally ruled out, because there is no fast way to verify that a decrypted system is in a safe state, or that encryption was the only change made to files.
- Restoration: after a long intrusion, ask whether backups can be trusted and how recovered systems will be validated as safe before they control a process. See the OT Backup, Recovery and Golden Image Guide.
- Network load: check that backup jobs cannot saturate links carrying time-critical safety messages.
- People on site: decide in advance whether staff will be sent to a site where an adversary may still be on the network.
- Discovery and patching: agree whether active scanning is acceptable or only passive discovery, and set patch frequency, testing and rollback rules per asset class.
2. Knowledge of the business is crucial
You cannot defend what you cannot rank. The guidance asks organisations to identify the vital systems needed to deliver critical services, understand each process and the significance of each part, map dependencies and external connections, and architect so vital systems can be defended from other networks. Its worked example is a generator: combine a top-down view (what service must be delivered) with a bottom-up view (what equipment that service physically needs) to find the minimum set that must keep running.
- Documentation: keep drawings, asset lists, network diagrams, access rights, recovery procedures, vendor lists and software bills of materials where possible. The OT Asset Register Template is a starting point.
- Integrated plans: fold OT incident response into emergency, crisis, business continuity and reporting plans, with process engineers in both planning and response.
- Third-party information pack: give responders and contractors contacts, naming conventions, data sources and approved tools before an incident.
This is the principle behind consequence-driven methods; see the Consequence-driven OT Risk (CCE) Guide.
3. OT data is extremely valuable and needs to be protected
Engineering configuration data such as network diagrams, controller logic and addressing conventions keeps its value to an adversary for years, because plants change slowly. Operational values, intellectual property and personal data also need protection. The guidance frames this as a set of questions about where OT data escapes:
- Copies outside OT: do vendors, technicians or consultants hold copies, and do engineers work from corporate IT where files are emailed, stored on laptops, included in corporate backups or synced to cloud storage?
- Security tooling: could endpoint detection or antivirus products upload OT files to a vendor cloud?
- Decommissioning: is PLC logic wiped when equipment is retired?
- Detection: use canary tokens on sensitive files, and alert on failed logins against changed default passwords.
- Data flow direction: design OT to push data out to consumers rather than letting external systems pull data in.
4. Segment and segregate OT from all other networks
Separation applies in four directions: from the internet, from IT, from other organisations' OT (peers, upstream suppliers and downstream customers), and between more and less critical systems inside OT, such as safety systems. Management and administration systems need their own separation, because whoever controls them controls everything they manage. See the OT Network Segmentation, Purdue Model and IEC 62443 Zones and Conduits Guide for zone and conduit design.
- Size does not set risk: the guidance notes that a connection to a small solar farm carries the same cyber risk as a connection to a large power station.
- Weak partners extend your boundary: if another organisation's network is poorly protected, treat it as inside your security boundary.
- Management direction: never manage a more critical environment from a less critical one.
- Directory design: Active Directory domains are not security boundaries within a forest, so an OT domain in the corporate forest is not segregated.
- Shared infrastructure: virtualisation and backup platforms administered by corporate privileged accounts may be lost in an IT compromise.
The Colonial Pipeline ransomware attack shows the cost of uncertain separation: attackers reached the IT network through an unused VPN account, and the company shut the pipeline down as a containment decision rather than because the controls were touched.
5. The supply chain must be secure
Many industrial control messages are unencrypted and can be seen or injected by almost any device on the network, so every device's supply chain matters, not only the engineering-significant ones. Scope includes peripherals, networking equipment and adjacent systems such as HVAC, fire and physical access control.
- Provenance: know where every device came from, and challenge repurposed lower-trust IT devices moved into OT.
- Vendor laptops: ask what other networks a vendor laptop has connected to before it joins yours.
- Behaviour testing: connect new devices to a packet analyser to see whether they contact unexpected remote addresses, and consider what a device could do if its firmware or configuration were changed.
- Firmware: require firmware from trusted sources, cryptographically signed and verified.
- Vendor maturity: treat practices that break OT principles, such as licence checks needing internet access from critical networks, as a mark against the vendor.
IEC 62443-2-4 (security programme requirements for IACS service providers) and 62443-4-1 (secure product development lifecycle) give contract language for these expectations. See the IEC 62443-4-1 and 4-2 Secure Product Development Guide.
6. People are essential for OT cyber security
Incidents cannot be prevented, detected or answered without trained, equipped people, and field technicians and operators are often the first to notice. The guidance recommends framing cyber requirements as workplace safety requirements and building mixed teams with IT, engineering, field operations and asset management skills.
- Engineering processes: include cyber in safety assessments, factory and site acceptance testing and change management, using methods such as Cyber-Informed Engineering, Cyber PHA and HAZCADS.
- Reporting culture: let staff report suspicious activity without ridicule; remote maintenance carried out without telling on-site staff is called out as a key concern.
- Fault diagnosis: teach operators to consider a cyber cause, because standard fixes such as rebooting or reflashing can erase the evidence an investigation needs. See the OT Incident Response Guide.
Applying them to decisions
The principles are most useful when written into the points where decisions are made. Work through them in this order:
- Agree pre-decisions with the board: record positions on ransom payment, sending staff to compromised sites, and the conditions for restoring from backup. Principle 1 makes these safety decisions, not IT decisions.
- Define the minimum viable operation: for each critical service, list the equipment, data, people and external connections it physically needs (Principle 2). This list sets segmentation priorities and the restore order.
- Find your OT data: run a data discovery exercise across email, file shares, engineering laptops, vendor portals and corporate backups, and decide what may leave OT (Principle 3).
- Review every connection: list internet, IT, partner and intra-OT connections, the management path for each zone, and whether any critical zone is administered from a less critical one (Principle 4). Use a test window and engineering sign-off for any change to firewall rules, with a documented rollback.
- Gate procurement and site access: add provenance, signed firmware, behaviour testing and vendor laptop rules to purchasing and permit-to-work (Principle 5).
- Change the engineering lifecycle: add cyber to PHA, FAT, SAT and management of change, and run a tabletop where operators diagnose a fault with a possible cyber cause (Principle 6).
| Decision | Principles that apply | What good looks like |
|---|---|---|
| Ransomware has encrypted the historian and HMIs | 1, 2, 6 | No payment by default; restore from validated golden images in minimum-viable order; preserve evidence before reimaging |
| New solar or wind site connecting to the control centre | 4, 5 | Same conduit controls as a large site; partner treated as inside the boundary until its security is assured |
| Vendor wants cloud analytics from the plant | 3, 4, 5 | Push-only data flow through a DMZ; no inbound pull; contract covers data held by the vendor |
| Proposal to put OT servers in the corporate AD forest | 4 | Rejected or redesigned: separate forest and separate privileged accounts for OT management |
| Recurring unexplained PLC faults | 2, 6 | Operators escalate to OT security before reflashing; logic compared against the known-good copy |
Small and large organisations
A small water utility or single-site manufacturer can apply all six principles with documentation and contracts before it buys any tooling: a one-page minimum viable operation list, a connection register and vendor access rules cover much of Principles 2, 4 and 5. See the Small Water Utility Cyber Security Checklist. Larger and multi-site operators need the formal programme of IEC 62443-2-1 and the risk assessment of 62443-3-2, with the principles used as a check that programme decisions still pass the safety and business tests.
Where identity fits
Several of the principles turn on identity. Principle 4 warns that corporate privileged accounts managing OT virtualisation or backups bring OT down with IT, and that a shared directory forest is not a boundary. Vendor remote access, service accounts in historians and shared engineering logins sit behind many OT intrusions. Give OT its own privileged accounts, broker vendor sessions with approval and recording, and inventory machine accounts used for data diodes and historians. See the OT Remote Access Guide.
Framework mapping
| Principle | NIST CSF 2.0 | NIST SP 800-53 Rev. 5 | ISO/IEC 27001:2022 Annex A | CIS Controls v8.1 |
|---|---|---|---|---|
| 1 Safety is paramount | PR.DS-11, RC.RP-03 | CP-9, CP-10, CM-3 | 8.13 | 11 |
| 2 Knowledge of the business | ID.AM-01, ID.AM-03, ID.AM-05 | CP-10 | 5.9 | 1 |
| 3 OT data | PR.DS-01 | SI-7 | 5.12 | 3 |
| 4 Segment and segregate | PR.IR-01 | SC-7, AC-17, MA-4 | 8.22 | 12 |
| 5 Supply chain | GV.SC-05, GV.SC-07 | SR-3, SR-4, SR-11, SA-9 | 5.19, 5.21 | 15 |
| 6 People | PR.AT-01, RS.MA-01 | AT-3 | 6.3 | 14 |
In MITRE ATT&CK for ICS, the techniques these principles most directly counter include T0886 Remote Services, T0866 Exploitation of Remote Services and T0859 Valid Accounts, which depend on the weak separation and unmanaged vendor access that Principles 4 and 5 address.
Measuring progress
- Pre-decisions recorded: board-approved positions exist for ransom, restoration and staff safety, reviewed within the last 12 months.
- Vital system coverage: percentage of critical services with a current minimum viable operation list and dependency map.
- Connection hygiene: number of OT zones administered from a less critical zone (target zero) and percentage of external connections with a named owner and review date.
- Data containment: count of OT engineering files found outside OT in discovery sweeps, trending down.
- Supply chain gate: percentage of new OT devices that passed provenance and behaviour testing before installation.
- People readiness: percentage of operators and field staff trained in cyber fault recognition, and number of suspicious events reported per quarter.
Common failure patterns
- Treating the principles as a poster: they are endorsed in a policy but never written into procurement, PHA, management of change or the incident plan, so nothing changes at the point of decision.
- Trusting backups without validation: restoring logic or images after a long dwell time without checking them against a known-good copy reintroduces the adversary or an unsafe configuration.
- Corporate control of OT infrastructure: OT virtual hosts, backups or domain controllers administered by corporate privileged accounts, so an IT ransomware event takes OT with it.
- Ranking connections by size: small partner sites and contractors given weaker conduit controls than large ones, despite carrying the same cyber risk.
- Engineering data in the corporate estate: drawings and PLC projects in email, shared drives and laptops, and security agents uploading OT files to a vendor cloud.
- Reflash first, ask later: operators fix recurring faults by rebooting or reflashing, destroying the evidence that would show a cyber cause.
Practitioner checklist
- Brief the board on the six principles and record pre-decisions on ransom payment, restoration and staff safety.
- Produce a minimum viable operation list and dependency map for each critical service.
- Run an OT data discovery sweep across IT systems, vendor portals and corporate backups, and set rules for what leaves OT.
- Confirm no OT zone is managed from a less critical zone and that OT does not share an Active Directory forest with IT.
- Apply the same conduit controls to every external OT connection regardless of the partner's size.
- Add provenance, signed firmware, packet analyser testing and vendor laptop rules to OT procurement and site access.
- Insert cyber into PHA, FAT, SAT and management of change, using Cyber PHA or Cyber-Informed Engineering.
- Train operators to escalate suspected cyber causes before rebooting or reflashing, and test this in an annual tabletop.
Standards and references
- ASD's ACSC and partners: Principles of operational technology cyber security
- NCSC New Zealand: Cyber security for operational technology
- NIST: SP 800-82 Rev. 3, Guide to Operational Technology (OT) Security
- ISA: ISA/IEC 62443 Series of Standards
- NIST: Cybersecurity Framework 2.0
- MITRE: ATT&CK for ICS Matrix
Related NHI Mgmt Group resources: OT Security Guide · IEC 62443 Guide · NIST SP 800-82 OT Security Guide · OT Security Checklist · IT Security vs OT Security