Joining TEFCA connects your organisation to nationwide health information exchange, and it also binds you to security, identity and incident duties that go beyond what many HIPAA programmes already test. The Trusted Exchange Framework and Common Agreement (TEFCA) links Qualified Health Information Networks (QHINs) into a network of networks, and every Participant and Subparticipant below them signs up to flowed-down terms. This guide is a health check: a structured way for health IT security and privacy leads, HIE operators and organisations joining through a QHIN to test their controls against the Common Agreement and the Standard Operating Procedures (SOPs) issued by the Recognized Coordinating Entity (RCE). It reflects Common Agreement version 2.1 and the SOPs published by the RCE as checked in November 2026; SOPs change often, so confirm the current versions before relying on any deadline. HIPAA itself is covered in the HIPAA Security Rule Guide.

Key takeaways

  • HIPAA becomes contractual for everyone. QHINs must apply the HIPAA Security Rule to TEFCA Information, and Participants and Subparticipants that are not HIPAA entities must comply with it as if they were, and encrypt identifiable data in transit and at rest.
  • QHINs carry extra assurance. They need third-party certification from an RCE pre-approved list covering all NIST CSF categories and NIST SP 800-171, an annual third-party technical audit with penetration testing, and a designated CISO.
  • The incident clock is 72 hours. Under the TEFCA Security Incident reporting SOP, the discovering entity reports no more than 72 hours after Discovery, and forwarding entities have one business day to pass reports on.
  • Patient-facing apps need IAL2 and AAL2. Individual Access Services (IAS) Providers must use RCE-approved credential service providers that proof identity to at least NIST IAL2 and authenticate users to at least AAL2.
  • Every request needs a purpose. Exchange is permitted only for a defined Exchange Purpose, so purpose-of-use controls, consent records and audit logs are what prove compliant sharing.

How to use this health check

Work through each section below, then score each area in the scoring table at the end. Use evidence, not intent: a policy that exists but has never been tested scores lower than a control that has been exercised and logged. Run the check before signing a QHIN, Participant or Subparticipant agreement, again before go-live, and then annually alongside your HIPAA risk analysis.

  • Who should take part: the CISO or security lead, the privacy officer, the integration or HIE technical owner, the identity team (for IAS), legal or contracts, and the incident response lead.
  • Evidence to gather first: your signed agreement and the Terms of Participation version it flows down, your latest HIPAA risk analysis, any certification or audit reports, your incident response plan, and logs from your exchange gateway or vendor platform.
  • Scoring scale: 0 not in place, 1 documented only, 2 implemented but not tested, 3 implemented, tested and evidenced.

TEFCA, QHINs and exchange purposes

TEFCA was created by the Office of the National Coordinator (now ASTP/ONC) under the 21st Century Cures Act to reduce barriers to sharing health records among providers, patients, public health agencies and payers. The Sequoia Project serves as the RCE under an ASTP/ONC contract awarded in August 2023: it maintains the Common Agreement, designates QHINs and monitors them. The HTI-2 final rule placed TEFCA provisions in a new 45 CFR Part 172, covering QHIN qualifications, designation, suspension, termination and appeals.

LayerWhoAgreement that binds themSecurity assurance expected
RCEThe Sequoia ProjectContract with ASTP/ONCOperates TEFCA-CIRT and the Cybersecurity Council
QHINDesignated networksCommon Agreement with the RCEHIPAA Security Rule for TEFCA Information, third-party certification, annual audit, CISO, cyber coverage
ParticipantProviders, HIEs, health IT developers, payers connected to a QHINParticipant agreement carrying the Terms of ParticipationHIPAA Security Rule (as if covered for non-HIPAA entities), encryption, incident reporting
SubparticipantOrganisations connected through a ParticipantFlowed-down Terms of ParticipationSame as Participant

Each transaction must state its Exchange Purpose. The initial purposes listed by ASTP/ONC are treatment, payment, health care operations, public health, government benefits determination and individual access services. Under the Terms of Participation, TEFCA Exchange may be used only for an Exchange Purpose, uses and disclosures must be consistent with your published Privacy and Security Notice, and where law requires an individual's consent or authorisation it must be obtained first, with a way to revoke it. Interoperability without a purpose check is the main data-sharing risk in a network of networks, because a query can reach many responders at once.

Governance and Common Agreement duties

Duties that apply to QHINs

Common Agreement dutyWhat it requiresEvidence to check
HIPAA Security Rule (12.1)Comply with the Security Rule for TEFCA Information whether or not the QHIN is a covered entity or business associateCurrent risk analysis scoped to exchange systems
Third-party certification (12.1.2)Certification from the RCE's pre-approved list; it must assess all NIST CSF categories and NIST SP 800-171 and review the HIPAA security analysisCertificate, scope statement covering in-scope systems
Annual assessment (12.1.3)Third-party technical audit at least annually, including internet-facing penetration testing and an internal vulnerability assessment; reports to the RCE within 30 daysAudit report, submission record
RemediationModerate and high findings remediated within 15 days or a plan of action and milestones (POA&M) sent to the RCE within 15 days, updated every 30 daysPOA&M tracker
CISO (12.1.6)A designated CISO responsible for the whole organisation's security posture for TEFCA, even if the role is subcontractedAppointment record, governance minutes
Cyber coverage (12.1.1)Insurance, self-insurance reserves or both, as set by SOPPolicy schedule
Vendor flow-down (13.2.2)Written agreements with vendors that access TEFCA Information must require Common Agreement complianceContract clauses, vendor register

Duties that apply to Participants and Subparticipants

  • Proportionate security (ToP 8.1): controls proportionate to risks to confidentiality, integrity and availability of identifiable information; non-HIPAA entities comply with the HIPAA Security Rule as if they were covered.
  • Encryption (ToP 8.5): non-HIPAA entities encrypt all individually identifiable information in transit and at rest, whether or not it came through TEFCA.
  • Offshore data (ToP 8.4): TEFCA Information may be used or disclosed outside the United States only where law permits and in line with the Security Rule. Check where your vendors host and support the service.
  • Privacy policy (ToP 7.2): a written privacy policy that is public and followed.
  • Vendor management: integration engines, cloud hosting and managed service providers that touch exchange traffic should be in your third-party risk programme. See the Third-Party Risk Management Guide.

Identity proofing and authentication

TEFCA raises two identity questions: who is the patient using an app to pull their records, and which systems and staff are allowed to query on an organisation's behalf.

Individual Access Services

The IAS Exchange Purpose Implementation SOP (version 3.0, March 2026) sets the identity bar for patient access:

  1. Approved CSPs only: IAS Providers may use only credential service providers approved by an RCE-selected approval organisation.
  2. IAL2 proofing: the CSP must verify identity to at least IAL2 as defined in NIST SP 800-63A, before first use of TEFCA Exchange, when verified demographics change and after credentials expire. See the NIST SP 800-63A-4 Identity Proofing (IAL) Guide.
  3. AAL2 authentication: IAS Providers must authenticate individuals to at least AAL2. See the NIST SP 800-63B-4 Authenticator Assurance Levels Guide.
  4. Signed claims: the CSP issues a signed IAL2 Claims Token in OpenID Connect format (RS256), and each IAS query carries it with verified demographics. The IAS Provider must check the token's audience claim matches its own identifier.
  5. Demographics Double-Check: from 1 August 2026, IAS Providers must compare returned demographics and reject mismatches, keep no patient identifier from a mismatch and notify the responding organisation.

The IAS Provider Requirements SOP (version 2.1, effective 17 March 2026) adds a plain-language Privacy and Security Notice, documented consent kept in an auditable log, separate consent for sale of data or targeted advertising, in-app revocation, deletion and export rights, and encryption in transit and at rest.

Workforce and machine identities

Most exchange traffic is system to system: an EHR or integration engine queries through a gateway using certificates and service credentials. Treat these as high-value non-human identities. Keep an inventory of every certificate, client credential and API key used for exchange, store private keys in an HSM or managed key vault, rotate on a schedule and on staff departure, and restrict which internal systems can call the gateway. Clinician access that triggers queries should use phishing-resistant MFA and role-based access tied to the treatment relationship. The Healthcare Identity Security Guide covers clinical identity in depth.

Security incident reporting

A TEFCA Security Incident is an unauthorised acquisition, access, disclosure or use of unencrypted TEFCA Information through TEFCA Exchange, subject to exceptions such as good-faith internal access, plus other events set by SOP that adversely affect participation. The TEFCA Security Incident Reporting SOP (version 1.0, July 2024) sets these timelines.

WhoReports toDeadline
QHIN, initial reportRCE (TEFCA-CIRT), likely impacted QHINs, likely impacted Participants and Subparticipants in its networkAs soon as reasonably practicable, no more than 72 hours after Discovery
QHIN, supplemental reportsSame recipientsAs information develops and at least every 24 hours until resolved
QHIN, post-incident reportRCEWithin 30 days after resolution
Participant or Subparticipant that discovers itUpstream QHIN, Participant or Subparticipant; actual incidents also to likely affected downstream entitiesNo more than 72 hours after Discovery
Entity receiving a reportUpstream and likely affected downstream entitiesOne business day
IAS ProviderAffected individualsWithout unreasonable delay, no later than 60 days after Discovery
  • Beyond data breaches: ransomware or a plausible ransom notice, extended denial of service affecting connectivity, persistent connectivity disruption, data corruption and a precautionary pause of TEFCA Exchange are all reportable events.
  • Not required: passive scans, phishing attempts, attempted access and thwarted exploits, though they may be reported voluntarily.
  • Do not wait: reports must not be delayed for incomplete information; send what you know and supplement.
  • HIPAA alignment: TEFCA reporting runs alongside, not instead of, HIPAA or FTC breach notification; the Common Agreement avoids duplicate notice where law already requires it. Map both clocks into one runbook. See the Healthcare Incident Response Guide.
  • Purpose of use enforcement: configure the gateway so every outbound query carries the correct Exchange Purpose code, and restrict which user roles and systems may assert each purpose. Treatment queries from a billing system are a red flag.
  • Responding obligations: Responding Nodes must answer queries for required Exchange Purposes with required information, but may withhold information where needed to comply with law. Document which state or federal rules (for example sensitive data categories) drive your withholding logic. See the Health Data Privacy Beyond HIPAA Guide (My Health My Data).
  • Consent records: where law requires consent, store who consented, to what, when and how it can be revoked, in a log that can be audited.
  • Audit logging: HIPAA audit controls (45 CFR 164.312(b)) apply. Log every query and response with requester identity, Exchange Purpose, patient match result and data returned, and keep logs where staff who make queries cannot alter them.
  • Monitoring: alert on query volume spikes per requester, queries outside business patterns, high patient-match failure rates and new requesting organisations.

Metrics

  • Percentage of exchange queries with a valid Exchange Purpose and authorised role (target 100%).
  • Time from Discovery to first incident report, against the 72-hour limit.
  • Open moderate and high audit findings past their POA&M dates.
  • Exchange credentials and certificates inventoried and within rotation policy.
  • Demographics Double-Check rejections per month, for IAS Providers.

Framework mapping

Health check areaNIST CSF 2.0HIPAA Security Rule
Governance and contract dutiesGV.OC-03, GV.SC-05164.308(a)(1) security management process
Identity proofing and authenticationPR.AA-02, PR.AA-03164.312(d) person or entity authentication
EncryptionPR.DS-01, PR.DS-02164.312(a)(2)(iv), 164.312(e)
Audit and monitoringPR.PS-04, DE.CM-01164.312(b) audit controls
Incident reportingRS.CO-02164.308(a)(6) security incident procedures
Vulnerability and audit findingsID.RA-01164.308(a)(8) evaluation

Scoring and next steps

Score each area 0 to 3 using the scale above. The maximum is 30.

AreaQuestion to answer with evidenceScore (0 to 3)
1. Agreement and flow-downDo we know which Common Agreement and Terms of Participation version binds us, and have we flowed it to vendors and Subparticipants?
2. HIPAA Security Rule coverageDoes our risk analysis cover exchange systems, including as a non-HIPAA entity if that applies?
3. Certification and audit (QHINs)Is certification current, scoped correctly, and was the annual audit submitted within 30 days?
4. EncryptionIs identifiable data encrypted in transit and at rest across gateway, integration and storage?
5. Machine identitiesAre exchange certificates and credentials inventoried, vaulted and rotated?
6. IAS identity (if offered)Do we use an approved CSP at IAL2 with AAL2 authentication and the Demographics Double-Check?
7. Purpose and consentIs every query tagged with an authorised Exchange Purpose and is consent logged where required?
8. Audit logging and monitoringCan we reconstruct who queried what, why and what was returned, and do alerts fire on anomalies?
9. Incident reportingDoes our runbook meet the 72-hour, 24-hour update and one business day forwarding rules alongside HIPAA notification?
10. Offshore and vendorsDo we know where vendors host and support exchange data, and is it lawful and aligned with the Security Rule?
  • 25 to 30: ready; keep evidence current and re-run annually.
  • 15 to 24: fix any area scoring 0 or 1 before go-live, starting with incident reporting and encryption.
  • Below 15: pause onboarding and agree a remediation plan with your upstream QHIN or Participant.

Any area at 0 is a blocker whatever the total. Track actions in a single register owned by the CISO, and review the RCE's SOP page each quarter for new or revised SOPs.

Common failure patterns

  • Treating TEFCA as a HIPAA rerun. The 72-hour reporting clock and the IAS identity rules are contractual additions that a HIPAA-only runbook will miss.
  • Certifying the wrong scope. A certificate that covers corporate IT but not the exchange gateway and integration engine does not meet the in-scope systems test.
  • Shared gateway credentials. One certificate used by many internal systems makes it impossible to attribute queries or revoke one system.
  • Purpose codes set by default. Hard-coding one Exchange Purpose for every query hides misuse and defeats audit.
  • Forgetting downstream forwarding. Entities receiving an incident report have one business day to pass it on, which needs a named on-call contact.

Practitioner checklist

  • Confirm the Common Agreement, Terms of Participation and SOP versions that apply to you and record the date checked.
  • Extend your HIPAA risk analysis to every exchange system and vendor.
  • Encrypt identifiable data in transit and at rest end to end.
  • Inventory, vault and rotate every exchange certificate and credential.
  • Enforce Exchange Purpose by role and system, and log every query and response.
  • For IAS, contract an approved CSP at IAL2 and enforce AAL2 and the Demographics Double-Check.
  • Merge TEFCA and HIPAA notification timelines into one tested runbook.
  • Re-run this health check annually and after any SOP change.

Standards and references

Related NHI Mgmt Group resources: HIPAA Security Rule Guide · Healthcare Identity Security Guide · Healthcare Cyber Regulation Map · Health Data Privacy Beyond HIPAA Guide (My Health My Data). This guide summarises TEFCA obligations and is not legal advice.

PDF for subscribers

Take this guide with you

Every section, table and checklist in one PDF, with links to the sources and related guides. Subscribe to our weekly NHI & AI Identity Journal and we’ll email you a download link.

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

PDF Downloads for Newsletter Subscribers

Get the guide

Enter your details and we’ll email you a download link.

The full guide is free to read online. The PDF is a thank you for subscribing.

Fill in all fields marked * and tick both boxes to continue.