Join our Newsletter — 33% off our NHI Course
Home› Guides› Cybersecurity for Architecture and Engineering Firms: Project Data,…
Guide Risk Management

Cybersecurity for Architecture and Engineering Firms: Project Data, CAD and Client Duties

← All guides
By NHI Mgmt Group, edited by Lalit Choda Updated 14 November 2026 15 min read
On this page

Architecture and engineering practices hold the most detailed picture of a building that will ever exist, yet most run on shared file servers, open project extranets and CAD workstations set up for speed rather than control. A design firm's risk is different from a contractor's: there is less site equipment and fewer payment runs, but far more intellectual property, client-sensitive drawings and files exchanged with dozens of outside parties. This guide covers the controls that are specific to design practices: securing CAD and BIM files and the scripts that run inside them, running project extranets and file sharing safely, meeting client and data protection duties, and lining up professional indemnity and cyber insurance. It is written for practice principals, IT managers and BIM or CAD managers in architecture, structural, building services and civil engineering firms. Site, plant and contractor topics are covered in the Cybersecurity for Construction Guide, which this page builds on rather than repeats.

Key takeaways

  • Design files are executable surfaces. CAD templates, LISP routines and plug-ins run code on open, so a drawing from a client or partner can be a malware carrier, not just data.
  • The extranet is the perimeter. Most leaks come from project links that never expire, shared logins and partner accounts left open after handover.
  • Clients set the security bar. Security-sensitive projects arrive with requirements under a security-minded approach based on ISO 19650-5, and the practice must be able to show it meets them.
  • Insurance needs a deliberate check. Professional indemnity responds to claims about your professional services; who pays for your own ransomware recovery or a misdirected fee is a separate question to settle with a broker.
  • Small practices can cover most of the risk cheaply. Locked-down CAD loading, MFA on email and extranet, expiring share links, immutable backups and call-back on bank details remove most realistic scenarios.

What makes design firms different

A contractor's main exposure is money moving between many short-lived parties. A design practice's main exposure is information: concept options before planning, structural calculations, building services layouts, security and access arrangements, and survey data about existing buildings and their occupants. That information is shared early and widely, often before contracts are signed, and much of it outlives the project.

AssetWhere it usually livesWho wants itHarm if lost or altered
CAD drawings and BIM modelsFile server or NAS, cloud CAD or BIM platforms, local workstation cachesRansomware groups, competitors, foreign intelligence on sensitive projectsProgramme delay, IP loss, physical security risk for the finished building
Calculations and design reportsAnalysis software projects, document managementFraudsters seeking credibility, litigantsIntegrity disputes, professional liability claims
Client-sensitive drawings (security, plant rooms, access control)Restricted project folders, client CDEHostile reconnaissanceBreach of client security requirements, loss of future work
Survey data, photographs, occupant and staff detailsSurvey apps, point cloud stores, shared drivesData thievesData protection breach and notification duties
Fee invoices and bank detailsFinance mailbox, accounting platformBusiness email compromise gangsLost fees, misdirected client payments

The design practice threat picture

ThreatHow it shows up in a practiceATT&CK techniquePriority control
Malicious CAD contentA template, drawing or script pack downloaded from a portal or sent by a partner runs code when openedT1204.002 Malicious File; T1080 Taint Shared ContentRestrict executable loading to trusted folders, block script file types at the mail gateway
Ransomware on project storageLarge, flat shares mapped on every workstation; one compromised account encrypts years of projectsT1486 Data Encrypted for Impact; T1039 Data from Network Shared DriveLeast-privilege project shares, immutable and offline backups, MFA on remote access
Extranet and cloud share exposureAnyone-with-the-link shares, accounts for ex-partner staff, download of whole project setsT1530 Data from Cloud Storage; T1078 Valid AccountsNamed accounts, expiring links, download alerts, close-out reviews
Partner and consultant compromiseA sub-consultant's mailbox or extranet account is used to send lures or pull filesT1199 Trusted Relationship; T1566 PhishingPartner access by project, MFA required for external users, supplier security terms
Fee and payment fraudFake "change of bank details" for the practice or a sub-consultantT1657 Financial TheftCall-back to a known number, dual approval of bank detail changes
Departing staff and project filesLeavers copy portfolios that include client-confidential drawingsT1567 Exfiltration Over Web ServiceClear portfolio rules, offboarding checklist, endpoint DLP for sensitive projects

Malicious CAD content is not theoretical. In 2012 ESET analysed ACAD/Medre.A, an AutoLISP worm that spread through a booby-trapped AutoCAD template posted on a public body's website in Peru, which firms working with that body were urged to download. It emailed drawings to accounts at two Chinese email providers, and ESET estimated that tens of thousands of drawings leaked. The lesson still holds: a template or drawing from a trusted source can carry code, and the CAD application will run it unless told not to.

Securing CAD and BIM files and workstations

CAD and BIM platforms support automation through scripts and plug-ins, and that automation runs with the user's rights. Treat the CAD environment like any other application that runs macros. In AutoCAD, the controls are documented system variables; other platforms offer their own add-in and script trust settings, so apply the same principles to every design tool you use.

ControlSetting or practiceWhy
Restrict executable loading (AutoCAD)SECURELOAD = 2 so executable files load only from folders listed in TRUSTEDPATHS; lock the value through the CAD deploymentAutodesk documents 1 as the default (trusted folders only, warning for others) and 0 as legacy behaviour it does not recommend
Trusted foldersTRUSTEDPATHS points at a read-only network or local folder managed by the CAD manager, never at project folders or DownloadsUsers cannot drop a script beside a drawing and have it load
Script and plug-in file typesBlock or quarantine .lsp, .fas, .vlx, .dvb and .arx attachments at the mail gateway; release only through the CAD managerThese are the AutoLISP, VBA and ObjectARX formats that execute inside AutoCAD
Template and block library sourcesDownload templates from portals only to a quarantine folder, scan, and publish to the standard library after reviewMedre.A spread through exactly this route
Plug-in inventoryKeep an approved list of add-ins per design platform, with owner and update sourceUnapproved plug-ins are a supply chain risk and are rarely patched
Workstation privilegesNo standing local admin for designers; use managed installs for software and plug-insLimits what a malicious file or plug-in can change. See the Engineering Workstation Security Guide

In AutoCAD 2026-based products, Autodesk documents that when PROJECTAWARE is set to 1, SECURELOAD becomes read-only at 2, which suits practices that want enforcement without separate locking. Confirm these settings against Autodesk's current documentation for your release, since behaviour can change between versions.

Large model files change how you back up. Point clouds and federated models run to tens or hundreds of gigabytes, so daily full copies are often replaced by snapshots. Make sure at least one copy is immutable or offline and that restores of a full live project are tested, not just single files. See the Backup Security and Immutable Backup Guide.

Project extranets and file sharing

Every project needs a place to exchange drawings with clients, contractors and sub-consultants. Whether that is a common data environment (CDE) set by the client, the practice's own cloud storage, or a dedicated extranet, the same rules apply.

  1. One workspace per project: create a separate site, folder tree or project in the platform for each job, with access granted by project role, not to the whole practice library.
  2. Named accounts only: no shared "projectteam@" logins for partners. Require MFA for external users, either through the platform or by trusting the partner's own identity provider.
  3. Links that expire: disable or restrict anonymous links; set a default expiry (for example 14 or 30 days) and require sign-in for anything marked sensitive. See How to Audit Google Drive External Sharing and Public Links for the audit pattern.
  4. Sensitive folders apart: keep security, access control and critical plant drawings in a restricted area with a named list of people, view-only or watermarked where the platform supports it.
  5. Close out on handover: at practical completion, archive the workspace, remove external accounts and links, and record what was handed to the client and in what form.
  6. Review quarterly: list guest users and active external links per project and remove anything with no project owner. See How to audit guest and external users.

For sensitive assets, the UK National Protective Security Authority (NPSA) recommends an information handling strategy based on ISO 19650-5, the international standard for security-minded information management in BIM and other built environment work. NPSA guidance for clients of major infrastructure projects expects consultants to receive the client's security requirements at RIBA Stage 1 and to produce a security strategy at Stage 2, updated at Stages 3 and 4. It also points to provisions for keeping sensitive information out of planning submissions and to the IET and NCSC Code of Practice for cyber security in the built environment. If you choose a commercial platform for this work, the Secure File Sharing and Virtual Data Rooms buyer's guide lists the evaluation criteria.

Client duties: contracts, sensitive projects and personal data

  • Client security requirements: read the appointment, information requirements and any security schedule at bid stage and price the controls. ISO 19650-5 sets out a proportionate, security-minded approach that includes monitoring and auditing compliance, so expect to show evidence, not just sign a clause.
  • Need-to-know on sensitive projects: keep a named list of staff and sub-consultants with access to restricted information, brief them on handling rules, and avoid publishing images or details of the project in portfolios, awards entries and social media without client approval.
  • Personal data: surveys of occupied buildings, photographs, staff lists and residents' details are personal data. Under UK and EU GDPR, Article 32 requires security appropriate to the risk, and where the practice processes personal data on a client's behalf, Article 28 requires a written contract setting out processor duties. Check which role you hold on each job.
  • Sub-consultants: flow down the client's security terms and require MFA, named accounts and incident notification from every firm with extranet access. See the ISO/IEC 27036 Supplier Relationships Guide.
  • Baseline certification: many public and private clients ask for Cyber Essentials or equivalent evidence in tenders. See the Cyber Essentials Guide.

Professional indemnity and cyber insurance

Professional indemnity (PI) insurance is part of practice for architects and engineers; the UK Architects Registration Board expects architects in business to hold adequate insurance, usually PI, under Standard 4 of the Architects Code. Cyber incidents sit awkwardly across policies, because the same event can produce a client claim, your own recovery costs and a fraud loss. Work through these questions with your broker before an incident, not after.

ScenarioQuestion for the brokerEvidence insurers usually ask about
A client sues because confidential drawings leaked from your extranetDoes the PI policy respond, or does it exclude data and cyber events, and does the cyber policy cover third-party liability?Access controls, MFA, sharing policy, incident response plan
Ransomware encrypts live projects and you miss deliverablesWhich policy covers incident response, data restoration and business interruption, and what waiting period applies?Backups, offline copies, restore tests, patching of remote access
A client pays a fee into a fraudster's account after a spoofed email from youIs social engineering fraud covered, under which policy, and with what sub-limit?Call-back procedure, email authentication, finance training
A design error is traced to a file altered by an intruderHow will the PI and cyber insurers deal with a claim that has both a negligence and a cyber element?Version history, file integrity records, audit logs

See the Cyber Insurance Guide and Identity Controls for Cyber Insurance Questionnaires Guide for how underwriters assess controls.

Where identity fits

Design practices rely heavily on freelancers, sub-consultants and client staff, so most access risk is external identity. Give every external person a named account with an end date tied to the project, and remove it at close-out. Non-human accounts matter too: CAD licence servers, render farm and plotter service accounts, scan-to-folder accounts on multifunction printers and sync tools that copy project data to the cloud often use static passwords with broad share access. Inventory them, give each the minimum folder rights, and rotate their credentials when staff with knowledge of them leave. See Construction Identity Security for project-based lifecycle patterns.

Rolling it out

  1. Inventory (weeks 1 to 2): list project storage locations, extranet platforms, external accounts, active share links, design applications and plug-ins, and service accounts.
  2. Quick wins (weeks 2 to 4): MFA for all email, extranet and remote access; call-back rule for bank detail changes; block script file types at the mail gateway; disable anonymous links by default.
  3. CAD lockdown pilot (weeks 4 to 8): set SECURELOAD and trusted folders for one studio, log which scripts users need, add approved ones to the trusted folder, then roll out practice-wide. Roll back by restoring the previous CAD profile for the affected group if a deadline is at risk.
  4. Storage restructure (months 2 to 4): move from one practice-wide share to per-project permissions, start immutable backup copies and run a full-project restore test.
  5. Extranet governance (months 3 to 6): per-project workspaces, link expiry defaults, quarterly guest reviews and a close-out checklist built into the project stage plan.
  6. Client evidence pack (ongoing): keep a short document describing these controls, with Cyber Essentials or ISO 27001 certificates, to answer tender questionnaires quickly.

Decision guidance by practice size

PracticeFocusTypical approach
Studio under 20 staffEmail, backups, CAD lockdown, extranet linksCloud storage with per-project folders, Cyber Essentials, outsourced IT with a written scope. See Choosing an IT Support Provider or MSP Securely
Mid-sized, 20 to 250 staff, several officesProject storage permissions, partner access, PI and cyber alignmentNamed BIM or CAD manager owning trust settings, quarterly access reviews, endpoint protection with central logging
Large multidisciplinary consultancySensitive project handling, supplier assurance, data loss preventionISO/IEC 27001 certification, ISO 19650-5 aligned procedures, restricted enclaves for security-sensitive work, DLP. See the Data Loss Prevention (DLP) Guide

Detection and measurement

Log sign-ins and file activity on storage and extranet platforms, mail gateway blocks of script attachments, CAD load warnings where the platform records them, and changes to bank details in the accounting system. Alert on bulk downloads from a project workspace, new external sharing on restricted folders, and sign-ins to the extranet from new countries.

  • External access hygiene: share of external accounts with an owner and end date (target 100%).
  • Link exposure: number of anonymous or non-expiring links on live projects, trending to zero.
  • CAD trust coverage: share of design workstations with SECURELOAD at 2 and a managed trusted folder.
  • Close-out compliance: share of completed projects with external access removed within 30 days of handover.
  • Recovery readiness: time to restore a full live project in the last test.
  • Payment verification: share of bank detail changes with a recorded call-back.

Framework mapping

AreaNIST CSF 2.0NIST SP 800-53 Rev. 5Other
CAD script and plug-in controlPR.PS-05CM-7, SI-3ATT&CK T1204.002, T1080
Project storage and extranet accessPR.AA-05AC-3, AC-21ISO 19650-5 security-minded information management
Data at rest and backupsPR.DS-01, PR.DS-11CP-9ATT&CK T1486
Sub-consultants and suppliersGV.SC-05SR-6ISO/IEC 27036
Personal data in surveys and project recordsPR.DS-01AC-21UK and EU GDPR Articles 28 and 32

Common failure patterns

  • Everyone maps everything: a single practice-wide share means one phished account can read or encrypt every project the firm has ever done.
  • Trusted folders that are not trusted: TRUSTEDPATHS set to a writable project folder or the whole network drive, which defeats the control.
  • Extranets that never close: partner and freelancer accounts and anonymous links stay live years after handover.
  • Portfolio leaks: leavers or award entries publish images of security-sensitive projects without client approval.
  • Assuming PI covers cyber: the practice discovers after an incident that its own recovery costs or a fee fraud sit outside its PI policy.
  • Restores never tested at scale: backups exist, but nobody has restored a full federated model set, and the first attempt is during a ransomware incident.

Practitioner checklist

  • Set SECURELOAD to 2 (or the equivalent add-in trust setting on other platforms) with a managed, read-only trusted folder.
  • Block script and plug-in file types at the mail gateway and route them through the CAD manager.
  • Move to per-project storage permissions and remove practice-wide write access.
  • Require MFA for all staff and every external extranet user.
  • Disable anonymous links by default and set expiry on all external shares.
  • Build an access close-out step into the project stage plan at handover.
  • Keep an immutable or offline backup copy and test a full-project restore twice a year.
  • Agree with your broker in writing which policy responds to leak claims, ransomware recovery and fee fraud.
  • Flow down client security requirements to every sub-consultant with access.

Standards and references

Related NHI Mgmt Group resources: Cybersecurity for Construction Guide · Construction Identity Security · Engineering Workstation Security Guide · Invoice Redirection and Supplier Bank Detail Fraud Guide

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

NHIMG Editorial Note
Researched and written by the NHI Mgmt Group editorial team using AI tools, under the editorial direction of Lalit Choda. Facts are drawn from the sources listed on this page and checked by our automated quality process. Last updated 14 November 2026. Spotted an error? Use our contact page.
NHI Mgmt Group, the independent authority on Non-Human Identity, IAM and Agentic AI security. nhimg.org