A hospital cannot segment, patch or monitor connected medical devices it has not found, so a reconciled inventory of every networked clinical device, with an owner, a location and a risk rating, is the first job of any medical device security effort. Most hospitals hold three or four partial lists: the clinical engineering maintenance system, an IT asset tool, a network access control database and supplier spreadsheets. None of them agree. This guide is for the healthcare delivery organisation (HDO), not the manufacturer. It covers how to discover devices safely, what to record about each one, how to reconcile the sources, and how to rank devices so the security and clinical engineering teams fix the right ones first.

Manufacturer obligations and the wider device lifecycle are covered in the Medical Device Security Guide. Manufacturer disclosure forms and software bills of materials have their own page, the MDS2 and Medical Device SBOM Guide for Hospitals.

Key takeaways

  • The inventory belongs jointly to clinical engineering and security. Clinical engineering knows what the device does; security knows what it talks to.
  • Use several discovery sources and reconcile them. Passive network monitoring finds what is connected; the maintenance system knows what was bought and where it lives.
  • Avoid aggressive active scanning on clinical networks. Some devices can misbehave when probed; use passive methods first and test any active technique off the live network.
  • Record a small set of fields well: identity, location, clinical function, network details, software version, support status, owner and remote access route.
  • Rank risk by clinical impact and exposure together, not by vulnerability count alone.
  • Keep the inventory alive through procurement, onboarding and decommissioning gates, or it decays within months.
  • Asset inventory is an Enhanced goal in the HHS HPH Cybersecurity Performance Goals and a proposed HIPAA Security Rule requirement, so the work also supports compliance.

Why hospital device inventory is hard

  • Many sources of truth. Devices arrive through capital purchases, leases, research grants, supplier loans and departmental budgets. Not all pass through clinical engineering or IT.
  • Devices move. Infusion pumps, portable monitors and ultrasound carts change wards daily, and wireless devices change access points as they go.
  • Vendor-managed systems. Imaging modalities and laboratory analysers often come with supplier-run servers and remote support links that the hospital did not configure.
  • Fragile network stacks. Some older devices respond badly to unexpected traffic, which rules out many standard IT scanning approaches.
  • Hidden components. A single system, such as a picture archiving workstation or a monitoring central station, may contain several computers and an embedded operating system.
  • Building systems on the same network. Nurse call, medication cabinets, smart beds and building management devices often share VLANs with clinical devices and need the same treatment.

Regulation and standards (status checked November 2026)

The HHS HPH Cybersecurity Performance Goals include Asset Inventory as an Enhanced goal, described as identifying known, unknown (shadow) and unmanaged assets so vulnerabilities can be handled faster, mapped to CISA cross-sector goal 1.A and NIST SP 800-53 CM-8 and PM-5. The proposed HIPAA Security Rule update, published in the Federal Register on 6 January 2025, would require regulated entities to inventory their technology assets and map the movement of ePHI through their systems; the sources checked did not show it as final. See the HHS HIPAA Security Rule Update (2025 NPRM) Guide.

The FDA medical device cybersecurity page publishes safety communications and says health care facilities can reduce the risk of unauthorised access by implementing the recommendations in those alerts. An inventory that records make, model and software version is what lets you act on an alert the day it appears. The NCCoE practice guide NIST SP 1800-8, Securing Wireless Infusion Pumps, gives an HDO example architecture for one high-volume device class. This page is not legal advice.

Discovery methods and how to use them safely

SourceWhat it findsLimits
Clinical engineering maintenance system (CMMS)Purchased and maintained devices, asset tags, serial numbers, location, service contractsOften no network details; misses devices bought outside the process
Passive network monitoringDevices actually communicating, protocols, peers, firmware hints from trafficNeeds traffic from switch mirror ports or taps; quiet devices may be missed
Network infrastructure dataSwitch port tables, DHCP leases, wireless controller client lists, network access control recordsGives addresses and MAC data, not clinical meaning
Supplier recordsSystems the vendor installed, remote access links, embedded serversQuality varies; request it at contract renewal
Manufacturer disclosure (MDS2) and SBOMOperating system, network services, security features per modelPer model, not per device; may be out of date
Physical walk-downDevices in clinical areas, labels, connection typeSlow; use to validate, not to build

Safe discovery rules

  • Start with passive collection: mirror traffic from core and distribution switches serving clinical areas, and pull DHCP, wireless and switch data.
  • Agree any active query technique with clinical engineering and the manufacturer, test it on an out-of-service unit first, and run it outside peak clinical hours.
  • Never run broad vulnerability scans across clinical VLANs without that agreement.
  • Include wireless: infusion pumps and portable monitors usually connect by Wi-Fi, so the wireless controller is a key source.
  • Look for devices with direct internet exposure or unexpected outbound connections and treat them as urgent findings.

What to record for each device

Too many fields and the inventory is never finished; too few and it cannot drive action. The minimum record below is an NHI Mgmt Group recommendation.

Field groupFields
IdentityAsset tag, manufacturer, model, serial number, device class (for example infusion pump, patient monitor, CT scanner)
Location and ownerSite, department, ward or room, clinical owner, clinical engineering owner
Clinical functionWhat it does, which clinical service depends on it, whether it is life-sustaining or diagnostic
NetworkMAC and IP addresses, VLAN or segment, wired or wireless, observed peers and protocols
SoftwareOperating system and version, application version, firmware version, link to MDS2 and SBOM if held
SupportManufacturer support status, patch approval route, end-of-support date, service contract
DataWhether it stores or transmits ePHI, and to which systems
AccessLocal accounts and default credentials status, remote access route and supplier, integration accounts

The access fields are often missed. Devices and their servers use local accounts, shared service logins and integration credentials to send results to the EHR or the picture archive. Record them, change defaults, and link the credentials to an owner. Our Machine Identity in Healthcare guide covers these non-human identities.

Reconciling the sources

Reconciliation turns several partial lists into one trusted record.

  1. Pick a join key. MAC address links network data to devices; asset tag or serial number links the maintenance system. Map one to the other during onboarding.
  2. Match network-seen devices to CMMS records. Every device on the network without a CMMS record is a finding: unknown purchase, loan unit, research kit or a misclassified IT device.
  3. Match CMMS records to the network. Devices recorded as networked but never seen may be disconnected, decommissioned or on a segment you are not monitoring.
  4. Classify the unmatched. Work through them by department with clinical engineering. Track the unmatched count as a measure.
  5. Choose a system of record. Many hospitals keep the CMMS as the record and feed it network data; others use a dedicated device security platform that syncs back. Either works if one is authoritative.

Risk-ranking connected devices

Rank each device or device model on two axes and combine them.

AxisQuestions
Clinical impactIs it life-sustaining? Does a critical service stop without it? Does it hold or send ePHI? Are there spare units?
ExposureIs it reachable from the general network or the internet? Does it have vendor remote access? Is it out of support? Does it use default or shared credentials? Is there a known exploited vulnerability for its software?

A suggested scheme from NHI Mgmt Group: score each axis from 1 to 3 and treat any device scoring 3 on both as top priority. For known exploited vulnerabilities, check the CISA Known Exploited Vulnerabilities Catalog against recorded software versions, and check FDA and manufacturer safety communications for the model.

What to do with the ranking

  • High impact, high exposure: segment now, remove internet exposure, restrict vendor access to approved sessions, and agree a patch or replacement plan with the manufacturer.
  • High impact, low exposure: keep segmentation tight, monitor for change, plan lifecycle replacement.
  • Low impact, high exposure: reduce exposure quickly; these devices are footholds for lateral movement.
  • Low impact, low exposure: record and review at the normal cycle.

Keeping the inventory current

  • Procurement gate. No connected device purchase without clinical engineering and security sign-off, an MDS2 form, network requirements and remote access terms.
  • Onboarding gate. Devices get a record and a network segment before connection; network access control places unknown devices in a quarantine segment.
  • Change. Software updates, relocations and vendor changes update the record.
  • Decommissioning. Remove network access, wipe stored data, disable accounts and integration credentials, and close the record.
  • Review. Monthly reconciliation of network-seen and recorded devices; quarterly review of top-ranked devices by the cyber risk group.

For how device inventory fits a hospital-wide programme, see the Hospital Cyber Security Programme Guide.

A 90-day rollout for one hospital

Inventory projects stall when they try to cover every device at once. A phased start, suggested by NHI Mgmt Group, gets a usable result quickly and builds trust with clinical engineering.

Days 1 to 30: agree and collect

  • Agree the joint ownership model, the minimum record and the rules for safe discovery in writing with clinical engineering, estates and IT networks.
  • Export the maintenance system and the IT asset tool, and pull DHCP, wireless controller and switch port data for clinical buildings.
  • Start passive monitoring on the network segments serving critical care, theatres, emergency care and imaging.
  • Ask the top ten device suppliers by installed volume for their lists of installed systems, embedded servers and remote access links.

Days 31 to 60: reconcile the critical areas

  • Reconcile network-seen devices with maintenance records for the critical areas first, and walk the wards to resolve the unmatched devices.
  • Fill software version, support status and remote access fields for the highest-volume device classes, such as infusion pumps and patient monitors.
  • Flag any device with direct internet exposure, default credentials or unmanaged remote access for immediate action.

Days 61 to 90: rank and act

  • Apply the clinical impact and exposure ranking and present the top tier to the cyber risk group.
  • Agree segmentation changes and vendor access controls for the top tier, with clinical sign-off on any change window.
  • Switch on the procurement and onboarding gates so new devices join the record from day one.
  • Set the monthly reconciliation routine and publish the first coverage measures.

After 90 days, extend the same steps to outpatient sites, laboratories, research areas and building systems.

Detection and measurement

Once the inventory knows each device's normal peers and protocols, the same passive data can flag change: a device talking to a new external address, a new remote access session, a new protocol, or an unknown device appearing in a clinical segment. Feed these alerts to the security operations team with the device record attached so analysts know the clinical impact before acting. Suggested measures:

MeasureTarget direction
Share of network-seen devices matched to a record and ownerUp
Count of unmatched devices older than 30 daysDown
Share of top-ranked devices on segmented networksUp
Devices with default or shared credentialsDown
Devices with unmanaged vendor remote accessDown
Time from FDA or manufacturer alert to list of affected devicesDown

Framework mapping

ActivityHHS HPH CPGNIST SP 800-53
Discovery and recordAsset InventoryCM-8, PM-5
Segmentation of ranked devicesNetwork SegmentationAC-4, SC-7
Software version tracking and alertsMitigate Known VulnerabilitiesRA-5, SI-2
Default and shared credential removalUnique CredentialsIA-5
Supplier remote access and disclosureVendor/Supplier Cybersecurity Requirements; Third Party Vulnerability DisclosureSA-9, SR-2
Change monitoringDetect and Respond to Relevant Threats and TTPsSI-4

CPG to control mappings are taken from the HHS Cyber Gateway.

Common failure patterns

  • Buying a discovery tool and calling it the inventory, without assigning owners or reconciling with the maintenance system.
  • Active scanning without clinical engineering, causing device faults and a lasting ban on security tooling in clinical areas.
  • Ignoring wireless devices because discovery only covers wired switch ports.
  • Recording models but not versions, so a safety communication cannot be matched to real devices.
  • No procurement gate, so new devices arrive faster than the team can record them.
  • Vendor remote access not recorded, leaving always-on support links outside any control.
  • Building systems left out even though they share clinical networks.

Practitioner checklist

  • Agree joint ownership between clinical engineering and security.
  • Collect passive network data, DHCP, wireless and switch tables for clinical areas.
  • Agree and test any active discovery technique with the manufacturer before use.
  • Define the minimum device record and populate it for top device classes first.
  • Reconcile network-seen devices with the maintenance system monthly.
  • Record local accounts, integration credentials and vendor remote access per device.
  • Rank devices by clinical impact and exposure and act on the top tier.
  • Match recorded versions against the CISA KEV catalogue and FDA safety communications.
  • Add procurement, onboarding and decommissioning gates.
  • Report inventory coverage and top risks to the cyber risk group quarterly.

Standards and references

Related NHI Mgmt Group resources: Medical Device Security Guide · MDS2 and Medical Device SBOM Guide for Hospitals · OT Asset Visibility Guide · Enterprise IoT Security Programme Guide

PDF for subscribers

Take this guide with you

Every section, table and checklist in one PDF, with links to the sources and related guides. Subscribe to our weekly NHI & AI Identity Journal and we’ll email you a download link.

Free weekly newsletter

Subscribe to the NHI & AI Identity Journal

The latest on NHI and Agentic AI security – articles, research, breaches, news and events every week.

Bonus 33% off our NHI Course when you subscribe.

PDF Downloads for Newsletter Subscribers

Get the guide

Enter your details and we’ll email you a download link.

The full guide is free to read online. The PDF is a thank you for subscribing.

Fill in all fields marked * and tick both boxes to continue.