Pathology is the hidden dependency of almost every clinical pathway, so a laboratory that loses its information system can stop surgery, transfusion and diagnosis across a whole region within hours. This guide sets out how pathology and laboratory services should secure their laboratory information management system (LIMS), the analysers and middleware that feed it, the interfaces that carry orders and results, and the supplier relationships that so many laboratory networks now rest on.
It is written for laboratory managers, hospital and trust security teams, digital leads, and the procurement and contract teams who manage outsourced or partnership pathology. It does not repeat the network, imaging or messaging detail covered elsewhere: for those, see the Hospital Clinical Network Segmentation Guide, the DICOM and PACS Security Guide and the HL7 v2 and Clinical Interface Engine Security Guide.
Key takeaways
- A pathology outage is a clinical incident, not only an IT incident. Plan for the loss of results, blood matching and order communications, not just the loss of servers.
- The LIMS is the crown jewel, but the attack surface is wider: analyser workstations, middleware, interface engines, results portals, courier and sample tracking systems, and the identities that connect them.
- Many laboratories are run by partnerships, networks or commercial suppliers. When the supplier is hit, every hospital and GP practice that relies on it is hit too, so supplier dependence must be governed as a board-level risk.
- Analysers are often supplier-maintained devices with old operating systems and remote support links. Treat them as medical devices with their own inventory, segmentation and remote access rules.
- Recovery depends on tested manual and paper downtime procedures, alternative laboratory capacity agreed in advance, and backups that attackers cannot reach.
- Data exposure can take far longer to resolve than service restoration. Know which data sits on shared drives and working areas, not only in the primary databases.
Why pathology and laboratories are different
Laboratories sit in the middle of the clinical workflow. Orders arrive from wards, emergency departments, outpatient clinics and primary care. Samples move through reception, analysers, validation and reporting. Results flow back to electronic patient records, GP systems and clinicians. Blood transfusion services depend on accurate group and crossmatch information in real time. When any part of this chain fails, the effect spreads far beyond the laboratory walls.
Several features make laboratories harder to secure than a typical hospital department:
- High integration density. A single LIMS may exchange messages with dozens of systems through an interface engine, and each analyser may connect through middleware that translates instrument output into results.
- Supplier-maintained equipment. Analysers are commonly leased or supplied under managed service contracts. The supplier controls patching, firmware and remote support, which limits what the laboratory can change.
- Long equipment life. Analysers and their control workstations are often in service for many years, which means operating systems can fall out of support while the instrument is still clinically sound.
- Shared and networked services. Pathology is often consolidated into hub and spoke networks or partnerships between trusts and commercial providers. Consolidation brings efficiency but concentrates risk.
- Accreditation and quality pressure. Changes to validated analytical systems must be controlled and documented, which can slow down security fixes if the change process is not designed with security in mind.
Threat picture: what Synnovis showed
The clearest recent example of laboratory supplier risk is the attack on Synnovis in London. According to Synnovis's own cyber incident update, Synnovis, a pathology partnership between Guy's and St Thomas' NHS Foundation Trust, King's College Hospital NHS Foundation Trust and SYNLAB, was the victim of a ransomware cyberattack on 3 June 2024. Synnovis states that the attack affected almost all of its IT systems and interrupted many of its pathology services.
The same update records that the criminals behind the attack published stolen data on 20 June 2024, and that Synnovis obtained a court injunction against further publication. Synnovis says the data was taken from working drives rather than its primary laboratory databases. Access to all services that were available before the attack was restored by late autumn 2024, but the investigation into whose data was affected took more than a year, with the forensic review concluding by the end of summer 2025 and notification of affected organisations completed by the end of November 2025. Synnovis also states that affected organisations, as data controllers, are responsible for notifying their own patients.
Three lessons stand out for any laboratory service:
- Concentration risk is real. One partnership provided pathology for more than one NHS trust, so one ransomware event interrupted services for every organisation that depended on it.
- Restoration and data resolution run on different clocks. Services came back within months; working out the data impact took well over a year. Plan resources for both.
- Unstructured data matters. Working drives, exports and spreadsheets held enough sensitive data to drive a long notification exercise, even though the primary databases were not taken.
Beyond ransomware, laboratories face the same threats as other clinical environments: phishing and credential theft against staff accounts, exploitation of internet-facing portals and remote access gateways, misuse of supplier remote support connections, and data theft from results portals. The Healthcare Incident Response Guide covers the general healthcare response pattern; this guide focuses on the laboratory-specific parts.
Securing the LIMS
The LIMS holds patient demographics, requests, results, audit trails and, in many cases, transfusion records. It is both the most valuable target and the system whose loss hurts most.
Access and identity
- Use named accounts for every user, including locum, agency and night shift staff. Shared bench logins make it impossible to investigate misuse and conflict with audit trail expectations.
- Tie LIMS accounts to the joiner, mover and leaver process so that access is removed when staff leave or change role. Review privileged roles such as validation, authorisation and system administration on a fixed schedule.
- Require multi-factor authentication for remote access, results portals and administrative access. For bench use, consider proximity or smartcard sign-in so that strong authentication does not slow sample processing.
- Inventory the service accounts, interface accounts and integration credentials that the LIMS uses to talk to other systems. These non-human identities often have broad rights and passwords that never change. The Healthcare Identity Security Guide covers this in more depth.
Hosting and resilience
- Know where the LIMS runs: on premises, in a supplier data centre, or as a hosted service. Each model changes who is responsible for patching, backups and incident response.
- Keep backups of the LIMS database, configuration, reference ranges, test catalogues and interface mappings in a location that ransomware cannot reach, and restore them in a test environment at least annually.
- Document the minimum data set needed to restart: test codes, reference ranges, user roles and interface definitions. Rebuilding these from memory during an incident is slow and error prone.
Audit and monitoring
- Send LIMS authentication and administrative events to central security monitoring, not only to the application audit log.
- Alert on unusual bulk exports, report generation outside normal hours, and new administrative accounts.
Analysers, middleware and laboratory workstations
Analysers and their control PCs are where clinical technology meets general purpose computing. They are often the least visible part of the estate to the security team.
- Inventory every instrument. Record model, serial number, control workstation operating system, software version, network address, supplier, support contract end date and remote access method. Feed this into the wider device inventory; see the IoMT and Hospital Device Inventory Guide.
- Segment analysers. Place analysers and middleware in a dedicated laboratory zone that can only talk to the middleware, LIMS and named supplier endpoints. Block general internet access and email from instrument workstations.
- Agree patching with the supplier. Contracts should state how quickly the supplier validates and applies operating system and application security updates, and what compensating controls apply when updates cannot be installed.
- Control removable media. Instrument PCs often accept USB media for software updates and quality control exports. Use scanned, dedicated media and record its use.
- Protect middleware. Middleware holds rules, autoverification logic and connections to every analyser. Back up its configuration and restrict administrative access as tightly as the LIMS.
- Treat analysers as medical devices. Many are regulated in vitro diagnostic devices. The Medical Device Security Guide covers procurement questions, software bills of materials and vulnerability handling.
Interfaces, portals and order communications
Orders and results travel through interface engines, order communications systems and results portals. Each connection is a path for attackers and a dependency in an outage.
- Map every interface the laboratory depends on: electronic patient record, GP systems, blood bank, theatre systems, referral laboratories and national reporting feeds. Record the direction, protocol, owner and the account used.
- Protect interface credentials and certificates as secrets. Rotate them when staff or suppliers change, and avoid sharing one account across several feeds.
- Put internet-facing results portals behind strong authentication and monitor them for credential stuffing and bulk downloads.
- Know how each interface fails. If the interface engine stops, do results queue, drop or need manual re-entry? The answer shapes the downtime plan.
Detailed messaging controls are in the HL7 v2 and Clinical Interface Engine Security Guide.
Supplier dependence and partnership governance
Supplier risk is the central lesson of Synnovis. Many trusts and health systems now buy pathology as a service, or run it through a joint venture. That makes contract terms and oversight as important as technical controls.
Questions to ask every pathology provider
- Which of our services depend on your systems, and which of your systems are shared with your other customers?
- What is your recovery time objective for LIMS, blood transfusion and urgent results, and when did you last test it end to end?
- Are your backups isolated from your production identity systems and administrative accounts?
- How do your staff and subcontractors access our systems, and is every connection protected with multi-factor authentication?
- What data of ours do you hold outside the primary LIMS, for example on shared drives, in reports or in exports?
- How quickly will you tell us about an incident, and who will speak to our clinical and communications teams?
- Which alternative laboratories have you agreed mutual aid with, and how are samples and results routed to them?
Contract and oversight controls
- Write security, notification and recovery obligations into the contract, with the right to receive test evidence and independent assurance reports.
- Include the provider in your incident planning and exercises, consistent with NIST CSF 2.0 outcome GV.SC-08, which expects relevant suppliers to be included in incident planning, response and recovery.
- Rank laboratory suppliers by criticality (GV.SC-04) and review the highest tier more often.
- Agree data handling at exit and after incidents, including who acts as controller and who notifies patients. Synnovis's statement that data controllers notify their own patients shows why this must be settled in advance.
For a structured approach to supplier assurance, see the ISO/IEC 27036 Supplier Relationships Guide and the NCSC supply chain security principles.
Downtime, mutual aid and recovery
When a LIMS is lost, the laboratory must keep the most urgent work going while systems are rebuilt.
- Prioritise tests. Agree with clinical leads which tests must continue in an outage, such as blood transfusion, urgent biochemistry and haematology for emergency and critical care, and which can be deferred.
- Keep paper processes current. Maintain printed request forms, results templates, sample logs and transfusion records, and practise using them.
- Arrange mutual aid. Agree in advance which laboratories can take overflow work, how samples will be transported and how results will be returned and later reconciled.
- Plan for blood. Transfusion is often the most time-critical service. Plan for manual group and crossmatch processes and for emergency stock policies.
- Reconcile after recovery. Results produced on paper or at other laboratories must be entered into the LIMS and patient record accurately. Assign staff and quality checks for this from the start.
- Restore in order. Restore identity and core infrastructure first, then the LIMS, then interfaces, then analysers and portals, checking for persistence at each step.
Hospital-wide downtime procedures are covered in the Clinical Downtime and EHR Downtime Procedures Guide. For ransomware preparation, the NCSC guidance on mitigating malware and ransomware attacks and the CISA #StopRansomware Guide are useful primary references.
Data on working drives and shared areas
Synnovis reported that stolen data came from working drives rather than primary laboratory databases. Most laboratories have similar stores: quality spreadsheets, audit extracts, referral lists, research datasets and exports created for reporting.
- Discover and classify shared drives used by laboratory staff. Remove patient-identifiable data that no longer needs to be there.
- Restrict access to shared areas by role, and remove access when staff leave.
- Monitor for large copies or uploads from file shares to the internet.
- Keep a record of what types of data are held where, so that an investigation after an incident can move faster.
Implementation: a phased plan
| Phase | Focus | Outputs |
|---|---|---|
| First 90 days | Visibility and supplier picture | Inventory of LIMS, middleware, analysers and interfaces; list of laboratory suppliers ranked by criticality; named accounts on the LIMS; multi-factor authentication on remote access |
| 3 to 6 months | Containment | Laboratory network zone; supplier remote access through a controlled gateway; isolated backups with a tested restore; clean-up of shared drives |
| 6 to 12 months | Resilience | Tested downtime procedures; mutual aid agreements; contract updates with notification and recovery terms; joint exercise with the main pathology provider |
| Ongoing | Assurance | Quarterly access reviews; annual restore and exercise; supplier assurance evidence reviewed by the risk committee |
Detection and measurement
Useful measures for a laboratory security programme include:
- Percentage of analysers and laboratory workstations in the inventory with a known owner, operating system and support end date.
- Percentage of laboratory systems behind segmentation rules that restrict them to named destinations.
- Number of shared or generic LIMS accounts still in use.
- Time since the last successful LIMS restore test, and time taken.
- Time since the last downtime exercise involving the laboratory and its main supplier.
- Number of critical laboratory suppliers with current security evidence on file.
Framework mapping
| Laboratory control | NIST CSF 2.0 outcome |
|---|---|
| Instrument and system inventory | ID.AM-01: inventories of hardware are maintained |
| Supplier criticality ranking | GV.SC-04: suppliers are known and prioritised by criticality |
| Ongoing supplier oversight | GV.SC-07: supplier risks are assessed and monitored over the relationship |
| Joint incident planning with providers | GV.SC-08: suppliers are included in incident planning, response and recovery |
| Named accounts and role reviews | PR.AA-05: access permissions are managed and reviewed with least privilege |
| Isolated, tested backups | PR.DS-11: backups are created, protected, maintained and tested |
| Downtime and recovery procedures | RC.RP-01: the recovery portion of the incident response plan is executed |
In MITRE ATT&CK terms, the main techniques to plan against are T1078 Valid Accounts for initial access through stolen credentials, T1190 Exploit Public-Facing Application for portals and gateways, and T1486 Data Encrypted for Impact for ransomware. Mitigations M1030 Network Segmentation and M1053 Data Backup map directly to the controls above.
Common failure patterns
- Treating the pathology provider's security as the provider's problem, with no contract terms, evidence or joint exercises.
- Shared bench logins on the LIMS and analyser workstations that cannot be traced to individuals.
- Analysers on the general hospital network with internet access and unsupported operating systems.
- Supplier remote support through always-on connections that nobody in the trust monitors.
- Backups that sit in the same domain as production and are encrypted alongside it.
- Downtime procedures written years ago, never tested, and missing blood transfusion steps.
- No plan for reconciling paper and mutual aid results back into the patient record.
- Patient data scattered across working drives with no record of what is held where.
Practitioner checklist
- Inventory the LIMS, middleware, every analyser and every interface, with owner and supplier.
- Rank laboratory suppliers by criticality and confirm security, notification and recovery terms in each contract.
- Remove shared LIMS logins and enforce multi-factor authentication on all remote and administrative access.
- Inventory and rotate interface and service account credentials.
- Segment analysers and middleware into a laboratory zone with named allowed destinations.
- Route all supplier remote support through a controlled, logged gateway.
- Keep isolated backups of LIMS data and configuration and restore them at least annually.
- Maintain and exercise paper downtime procedures, including transfusion.
- Agree mutual aid with alternative laboratories before you need it.
- Clean up and restrict laboratory working drives and shared areas.
- Run a joint exercise with your main pathology provider at least once a year.
Standards and references
- Synnovis: cyber incident update
- NCSC: Supply chain security principles
- NCSC: Mitigating malware and ransomware attacks
- NCSC: Cyber Assessment Framework
- CISA: #StopRansomware Guide
- NIST: Cybersecurity Framework 2.0
Related NHI Mgmt Group resources: Hospital Clinical Network Segmentation Guide · HL7 v2 and Clinical Interface Engine Security Guide · Healthcare Incident Response Guide · Medical Device Security Guide