Many federal door readers still accept a PIV card the way they accepted a proximity badge: they read a number and open the door, which gives almost none of the assurance the card was built to provide. NIST SP 800-116 Rev. 1 sets out how a physical access control system (PACS) should use the PIV card's cryptographic mechanisms, how many authentication factors each security area needs, and how credentials should be validated and revoked. This guide explains those authentication modes, how they line up with the current PIV standard, FIPS 201-3, and how to implement and test them at the door. It is written for federal physical security teams, PACS integrators and the identity engineers who run the PKI behind the cards. As checked in November 2026, SP 800-116 Rev. 1 (June 2018) is the current final revision and FIPS 201-3 (January 2022) is the current PIV standard.
Key takeaways
- Factors follow the area. SP 800-116 Rev. 1 requires one factor for Controlled areas, two for Limited areas and three for Exclusion areas, broadly matching FIPS 199 low, moderate and high impact.
- PKI-CAK is the one-factor baseline. A challenge-response with the mandatory asymmetric Card Authentication key proves the card is genuine and not cloned; reading the CHUID alone proves nothing and is no longer an authentication mechanism under FIPS 201-3.
- PKI-AUTH with a PIN is the two-factor workhorse. It is the recommended option for Limited areas and the alternate when fingerprints cannot be captured.
- Validation is part of authentication. Every mechanism needs signature and certificate path validation; revoked status must always deny access, and cached status should be refreshed at least every 24 hours.
- The two documents are over three years apart. SP 800-116 Rev. 1 predates FIPS 201-3, so read it alongside the newer standard, which removes CHUID authentication, adds SM-AUTH and deprecates SYM-CAK.
PIV and FIPS 201
FIPS 201 defines the Personal Identity Verification system required by HSPD-12: the identity proofing, issuance, card and infrastructure that let one federal credential open both doors and systems across agencies. FIPS 201-3 superseded FIPS 201-2 in January 2022. The card format and data model are specified in NIST SP 800-73 and the algorithms and key sizes in SP 800-78; the logical access side is covered in the Smart Card and PIV/CAC Authentication Guide. This guide stays at the door.
For physical access, four things on the card matter most:
- Card Authentication key and certificate: FIPS 201-3 makes this asymmetric key mandatory. It can be used without a PIN and over the contactless interface, which is why it suits turnstiles and doors.
- PIV Authentication key and certificate: also mandatory, but the card releases its use only after the PIN (or an on-card biometric comparison) is verified. This is what turns a card read into proof that the holder is present.
- Signed biometric data: fingerprint templates signed by the issuer, used by the BIO and BIO-A mechanisms for off-card comparison.
- Identifiers: the 25-byte FASC-N (whose 14-digit FASC-N Identifier is Agency Code, System Code and Credential Number), the mandatory 16-byte Card UUID, and an optional Cardholder UUID that persists across card replacements. FIPS 201-3 sets a maximum card validity of six years and no more than 10 consecutive activation retries.
SP 800-116 Rev. 1 covers PIV cards only. It notes that PIV-I cards do not meet every FIPS 201 requirement and that their FASC-N values may not be unique, so a PACS that accepts PIV-I should key access control lists on the Card UUID instead.
Authentication modes
SP 800-116 Rev. 1 describes each PIV authentication mechanism by the factors it provides: something you have (an authenticated card), something you know (the PIN) and something you are (a fingerprint). Its Table 4-1 assigns the counts below; FIPS 201-3 then updated the status of several mechanisms.
| Mechanism | What the reader verifies | Factors (SP 800-116 Rev. 1) | Contactless | Status under FIPS 201-3 |
|---|---|---|---|---|
| PKI-CAK | Challenge-response signed with the Card Authentication key; certificate path and status validated | 1 | Yes | Mandatory key; recommended one-factor mode |
| SM-AUTH | Card authenticated while secure messaging is set up, using the on-card secure messaging key and its Card Verifiable Certificate | Not in Rev. 1 (added by FIPS 201-3) | Yes | Optional key; FIPS 201-3 notes it gives no protection against a revoked card |
| SYM-CAK | Symmetric challenge-response | 1 | Yes | Deprecated; not interoperable across agencies and does not block revoked cards |
| BIO | Issuer signature on the stored fingerprint, matched to a live sample (PIN unlocks the read) | 1 | No | Active |
| BIO-A | As BIO, with an attendant supervising capture | 2 | No | Active |
| PKI-AUTH | Challenge-response with the PIV Authentication key after PIN (or OCC) activation | 2 | Through the virtual contact interface only | Mandatory key; recommended two-factor mode |
| OCC-AUTH | On-card fingerprint comparison over secure messaging, result verified by a message authentication code | 2 | Yes | Optional on cards, so not every card supports it |
| PKI-CAK or SYM-CAK plus BIO(-A) | Card authentication combined with biometric comparison | 3 | Partly | Use PKI-CAK; SYM-CAK is deprecated |
| CHUID (with or without VIS) | Issuer signature on a static data object | 1 in Rev. 1, deprecated | Yes | Removed as an authentication mechanism; the data object stays on the card |
| VIS | Guard inspects card and face | Little or no confidence | Not applicable | Deprecated as a standalone mechanism |
Three points trip up most designs:
- Reading is not authenticating. A reader that pulls the FASC-N or the CHUID and checks it against a list has not challenged the card. SP 800-116 Rev. 1 Appendix A describes the CHUID as easily cloned, and it has no revocation check. FIPS 201-3 says relying systems must not use it.
- BIO alone is only one factor. Matching a fingerprint without authenticating the card proves a person matches a template on some card, not that the card is genuine. Attendance (BIO-A) or a card challenge adds the missing factor.
- Do not depend on optional features. OCC and the secure messaging key are optional on cards. IDManagement.gov advises against access points that depend only on optional features, because some cardholders will not have them.
Assurance levels
SP 800-116 Rev. 1 builds on a simple area model. Space with no PACS control is Unrestricted; inside it, the three controlled tiers below take the risk level of the most sensitive asset they protect. The Facility Security Level assessment, under the Interagency Security Committee risk management process, comes first and drives which areas a building needs.
| Area | Typical example | Impact level (broadly) | Factors required | Mechanisms that meet it |
|---|---|---|---|---|
| Controlled | Lobby or buffer zone around inner areas | Low | 1 | PKI-CAK (SM-AUTH also listed by IDManagement.gov) |
| Limited | Office floors near a secure asset, where escorts can restrict access | Moderate | 2 | PKI-AUTH with PIN, BIO-A, OCC-AUTH |
| Exclusion | Space where movement gives direct access to an asset, such as a SCIF | High | 3 | PKI-AUTH with PIN plus BIO, or PKI-CAK plus BIO(-A) |
FIPS 201-3 expresses the same idea as confidence levels in its Table 6-1: PKI-CAK and SM-AUTH give some confidence, BIO medium, and BIO-A, OCC-AUTH and PKI-AUTH high, while VIS gives little or none. For comparison, its logical access table places PKI-CAK at AAL1 and PKI-AUTH at AAL3, which is a useful reminder that the PIN-less card key must never stand in for the PIV Authentication key on a network login. See the NIST SP 800-63B-4 Authenticator Assurance Levels Guide.
- Authentication in context: SP 800-116 Rev. 1 Section 4.3 lets an inner door require fewer new factors when the person has already been authenticated at an outer perimeter, but only where anti-tailgating and anti-piggybacking controls make that earlier check meaningful. Without mantraps, turnstiles or monitored doors, treat every door as standalone.
- Interface choice: mechanisms that need secure messaging over contactless may not be interoperable across agencies, so SP 800-116 Rev. 1 prefers the contact interface for them. For visitors from other agencies at Limited and Exclusion doors, plan a contact slot.
- Small sites versus campuses: a single-tenant building can often run PKI-CAK everywhere plus PKI-AUTH at a few internal doors. Multi-tenant federal buildings and campuses, covered in SP 800-116 Rev. 1 Section 5, need agreed registration and a shared approach to cards from other agencies.
Implementation
A PACS is an information system: IDManagement.gov notes that it still needs an assessment and an authority to operate before it joins the network, and that agency-purchased components should come from the GSA FIPS 201 Approved Products List (APL). The FIPS 201 Evaluation Program tests readers and infrastructure against approved PACS topologies before listing.
- Assess and zone. Run the Facility Security Level assessment, draw the Controlled, Limited and Exclusion boundaries and record the factor count per door in a door schedule.
- Choose mechanisms per door. PKI-CAK at Controlled doors, PKI-AUTH with PIN at Limited doors, and a three-factor combination at Exclusion doors. Remove CHUID and SYM-CAK modes from reader configurations, and keep VIS only as a supplement at staffed posts.
- Fix the transport. Legacy 26-bit Wiegand formats use an 8-bit site code and 16-bit card number, which allow only 256 sites and 65,536 cards and can collide; SP 800-116 Rev. 1 Appendix E notes that Wiegand is one-way and too small for a 14-digit FASC-N Identifier or 16-byte Card UUID. Move to bidirectional reader communication. See the Physical Access Control Systems Security Guide.
- Register cards before use. Preregistration is not mandatory but SP 800-116 Rev. 1 strongly recommends it. At registration, validate the certificate path to the Federal Common Policy root, store the Card UUID or FASC-N rather than the whole CHUID (Recommendation 6.1), and link the record to the cardholder in the agency's identity system.
- Stand up status checking. Use a caching status proxy that validates certificates at registration and revalidates them at least daily using CRL or OCSP, and deactivates access on revocation or expiry. Use online status checks at Exclusion doors and wherever current status is critical (Recommendation 6.2). See the Certificate Revocation Guide.
- Tune transaction time. PKI-CAK is slower than a static read. SP 800-116 Rev. 1 Appendix C points to ECC Card Authentication keys, careful reader placement and power, preregistration and the caching proxy as the main speed levers.
- Plan the exceptions. Temporary badges must be visually and electronically distinguishable from PIV cards; people whose fingerprints cannot be captured need PKI-AUTH with PIN at biometric doors; lost or suspicious cards go to the issuing security office, which decides on revocation.
- Roll out in rings and keep a way back. Convert a pilot floor first with the old mode logged but not trusted, then expand by building. Keep the previous reader profile archived so a reader can be reverted if throughput fails, and record every such reversion as a time-limited exception.
Where identity fits
The door decision is only as current as the identity data behind it. SP 800-116 Rev. 1 Section 6.7 asks for PACS integration with the agency's identity management and credentialing systems, so that a separation or card revocation removes building access within the same cycle as network access. The PACS also runs on service accounts and controller credentials (head-end database accounts, integration accounts that pull identity changes, panel administration logins) that deserve the same vaulting and review as any privileged non-human identity. Access rights themselves need periodic recertification; see the Physical Access Review Checklist. For mobile devices without a reader, see Derived PIV Credentials.
Testing
Test at three levels: the product, the door and the operating process.
- Product level: confirm every reader, controller and validation component is on the APL for the topology you deploy. The FIPS 201 Evaluation Program publishes its PACS Functional Requirements and Test Cases and offers a PACS self-assessment toolkit for agencies.
- Negative card tests: present a revoked card, an expired card, a card from an untrusted issuer, a card whose certificate chain fails, and a cloned static identifier. Each must be denied at every door type. A clone that opens a Controlled door means that door is still in a static read mode.
- Factor tests: at Limited doors, a correct card with a wrong PIN must fail; at Exclusion doors, card plus PIN without the biometric must fail.
- Status freshness tests: revoke a test card and measure how long until each door denies it. The answer should be within the cache window you designed, at most 24 hours, and immediate at online-checked doors.
- Failure mode tests: disconnect the validation service and record whether readers fail secure or fall back to an unvalidated mode; document the chosen behaviour per area.
Detection and measurement
Send PACS events to the SOC alongside logical access logs. Watch for repeated PIN failures at one reader, access by a card shortly after its revocation, door-forced and door-held alarms on Limited and Exclusion doors, and readers reporting a downgrade to a non-cryptographic mode.
| Metric | What good looks like |
|---|---|
| Doors using a mechanism that meets their area's factor count | 100%, with time-limited exceptions logged |
| Readers still accepting CHUID or SYM-CAK | Zero |
| Revocation-to-denial time | Within 24 hours everywhere; immediate at online-checked doors |
| Registered cards whose status check failed or is stale | Falling to zero, with daily review |
| Separations where building access outlived network access | Zero |
Framework mapping
| Framework | Reference | How this guide applies |
|---|---|---|
| NIST SP 800-53 Rev. 5 | PE-2, PE-3, PE-3(1), PE-6, PE-8 | Authorisations, enforcement at entry points, monitoring and visitor records |
| NIST SP 800-53 Rev. 5 | IA-2(12), IA-5(2) | Acceptance and electronic verification of PIV credentials; PKI-based authentication and path validation |
| NIST CSF 2.0 | PR.AA-01, PR.AA-03, PR.AA-06, DE.CM-02 | Credential management, authentication, physical access managed commensurate with risk, physical monitoring |
| ISO/IEC 27001:2022 Annex A | A.7.1, A.7.2 | Physical security perimeters and physical entry controls |
Common failure patterns
- PIV cards on a proximity-era system: the reader reads the FASC-N and the panel looks it up. Every door is effectively CHUID-only, which FIPS 201-3 no longer recognises as authentication.
- Using PKI-CAK at Limited doors: it is fast and contactless, so it spreads inward. It remains one factor; inner doors need a PIN or biometric.
- Validation done once: certificates are checked at registration and never again, so a revoked card keeps working until someone notices. Daily revalidation is the minimum.
- Fail-open validation: when the status service is down, readers quietly accept any card. Decide fail behaviour per area and alarm on the change.
- Disconnected identity data: PACS records are maintained by hand, so leavers keep building access. Integrate with the identity system and reconcile.
- Visitors from other agencies refused or waved through: no contact interface or no trust in their issuer forces guards back to VIS. Plan cross-agency registration up front.
Practitioner checklist
- Confirm you are designing to SP 800-116 Rev. 1 read together with FIPS 201-3, and record the date you checked their status.
- Build a door schedule listing each door's area, required factors and configured mechanism.
- Disable CHUID and SYM-CAK modes on every reader; keep VIS only as a supplement.
- Use PKI-CAK as the Controlled-area baseline and PKI-AUTH with PIN for Limited areas.
- Preregister cards with full path validation and store Card UUID or FASC-N, not full CHUIDs.
- Run a caching status proxy refreshed at least daily and online checks at Exclusion doors.
- Replace Wiegand links with bidirectional reader communication.
- Buy readers and validation components from the FIPS 201 APL for your topology.
- Test revoked, expired, cloned and untrusted cards at every door type, and measure revocation-to-denial time.
- Integrate PACS with the identity system and vault the PACS service accounts.
Standards and references
- NIST: SP 800-116 Rev. 1, Guidelines for the Use of PIV Credentials in Facility Access
- NIST: FIPS 201-3, Personal Identity Verification (PIV) of Federal Employees and Contractors
- NIST: FIPS 201-3 full text (PDF)
- GSA IDManagement.gov: PACS 101
- GSA IDManagement.gov: FIPS 201 Evaluation Program
- NIST: SP 800-53 Rev. 5, Security and Privacy Controls
- NIST: Cybersecurity Framework 2.0
Related NHI Mgmt Group resources: Smart Card and PIV/CAC Authentication Guide · Physical Access Control Systems Security Guide · Derived PIV Credentials · Physical Access Control Systems Buyer's Guide · D3-PAM Physical Access Mediation